MAN B&W ME: how cylinder prelubrication before start works
EL-0168 · Knowledge · rating 0 · occurred 27 Nov 2024
Source: /cases/el-0168
Notes#
Background
- The engine is a MAN B&W ME-type two-stroke main engine with Alpha cylinder lubricators.
- The ME hydraulic system pressure drives the lubricators.
- From the MOP (Main Operating Panel), the operator can start a pre-lubrication sequence (PRELUB).
- There was no fault and no alarm. A colleague had a general operating question.
The colleague's question
- When PRELUB is started from the MOP, how many injections does it give?
- During injection, what hydraulic pressure acts?
My answer
- One PRELUB activation gives
11injections. In my view, this gives enough oil to start the engine. - Starting the auxiliary blowers also starts a new PRELUB cycle.
- The lubricators work at ME hydraulic system pressure. At standstill this is about
225 bar. - To read the actual activating oil pressure downstream of the lubricator solenoid valve, connect a portable pressure gauge at position
565. - I then posted an image. What it shows is not described here.
Follow-up: piston position at standstill
The colleague raised a second point. When PRELUB is pressed at standstill, the piston is not always near the lubricator quills. So the oil may go in at the wrong point. Does this matter?
My reply:
- In my view, the timing at PRELUB is not a big problem. If cylinder lubrication was correct while the engine was running, the liners still hold some oil. Oil also stays in the ring grooves. PRELUB oil adds to this.
- For more certainty, I suggest turning the engine with the turning gear and activating PRELUB
2–3times while it turns. Then the oil enters at different piston positions. - I also said that if the oil supply fails badly during normal running, a MAN two-stroke engine can keep running for about
15 minwithout cylinder lubrication. This is my own statement. I did not quote any MAN document. Do not treat it as a confirmed limit, and do not use it as a reason to start or run without cylinder oil. - I find the Alpha Lubricator reliable. The same algorithm is used on ME-B/C engines.
Outcome
The colleague thanked me. They said they already knew this information.
Not stated
- Oil quantity per injection.
- Feed rate setting.
- Exact engine model.
- Any MAN service letter number.
Comments · 0