Tanker P/V valves: clean often, lap pitting early, keep a spare
EL-0186 · Procedure · rating 0 · occurred 04 Aug 2022
Source: /cases/el-0186
Scope#
P/V (pressure/vacuum) valve care on tankers comes down to cleaning the discs and seats often, lapping pitting while it is still shallow, and always keeping a spare valve on board. A tanker is only safe if these valves open as designed and do not leak when closed.
This is good practice from my experience. It cites no regulations, class rules or maker letters, and is not tied to a particular valve maker or model.
Safety#
- Depressurise the tank before you open the valve.
- Do not put silicone or any other compound on the sealing faces.
- Keep one spare P/V valve on board at all times, so a tank is not left without a working valve.
Tools & parts#
- Clean cotton rags
- Self-adhesive emery paper, or normal emery cloth with double-sided adhesive tape
- Spare P/V valve (onboard spare)
- P/V valve test device
- Soapy water
- Maker's instructions for lapping
Steps#
- Clean the discs and seats often with clean cotton rags. If the ballast leg is long enough, do this once every ballast voyage. Keeping the faces clean helps to avoid pitting.
- Check often that the valve lifts freely, using the manual lifting handle.
- If you find pitting, lap the surfaces as soon as possible, following the maker's instructions. Act while the pitting is still shallow. Deep pitting cannot be lapped out; the seat then needs re-welding and machining by a specialist.
- For lapping, fit the onboard spare valve in place of the pitted valve and take the pitted valve to the workshop.
- Lap the faces with self-adhesive emery paper, or with emery cloth fixed by double-sided tape.
- When lapping is done, remove all glue residue from the faces.
- Do not machine out pitting on the ship's lathe. The sealing faces will most likely not get the correct matching seat angles. Leave this work to specialists.
- Test the lapped valve (see Check after), then fit it back in place of the spare.
Check after#
- Leak-test the lapped valve on the P/V valve test device with soapy water.
- Compare the leak rate and the pressure values with the shop test values. They should be close. I don't have figures, set points or leak limits to give here.
Comments · 0