Log inJoin

Open-loop SOx scrubber: common problems with pipes, sensors and pumps

OtherPumps

Notes#

These are the usual trouble spots on SOx scrubbers, from my experience and from one other engineer. We both talk about open-loop systems. I do not name a ship, engine or scrubber maker here. This is a list of experience, not one breakdown. One of us made the point that the weak points depend on the maker, the scrubber design and the equipment around it.

Overboard discharge pipes

  • The wash water is acidic. The overboard pipes suffer pitting corrosion.
  • The other engineer said makers have started to fit GRE (glass-reinforced epoxy) pipe. In their view it seems reliable.
  • I first saw ceramic paint used on its own, inside the pipe and on the hull plating around it. That coating-only method failed completely.
  • The newest fix that I have seen working: a 6 mm SMO (super-austenitic steel) sleeve with ceramic paint on the inside, and epoxy putty filling the gap between the sleeve and the sea tube.
  • GRE lining and a double-wall pipe with a leak indicator are other options I know are in use.

GRE pipe vibration

  • Vibration is a problem for GRE pipes. It can loosen bolts and supports, and the pipe may then crack.
  • Inspect the pipe supports at short intervals.
  • Have repair material on board. Ordinary epoxy resin with glass cloth (Cordobond was one example) can be used.

Scrubber tower

  • Sulphuric acid attacks the tower. Inspect the nozzles, the nozzle pipes, the demister/absorber section and the tower shell for cracks and corrosion.

Seawater pumps

  • On some retrofits the old sea chests and pipe sizes were kept. The water then flows faster than before.
  • This caused cavitation damage to the pump casings and impellers. Check the pump condition.

Wash water monitoring system (WMS) sensors

  • Sensors often fail: turbidity, PAH, pH and "PT" sensors. Not known: what PT means.
  • Hold spare sensors, above all for the outlet WMS.
  • Check sensor accuracy as often as the maker says. Check again any time a reading looks doubtful.
  • Have buffer solutions and a spare pH sensor on board.
  • One of us pointed to IMO MEPC.1/Circ.883 for what to do when one sensor fails. No details were given. Read the circular itself.

Membrane pumps (WMS and gas monitoring system)

  • These pumps break down. Have either a complete spare pump or the parts to overhaul one.

Gas monitoring cabinet and analyzer

  • Renew the air filters and ceramic filters when the maker's schedule says so.
  • One of us said the analyzer fault they see most is a blocked sample line or gas filter. Electrical and electronic faults are also common.
  • The same engineer suggested what to do while the analyzer is down, so that compliance can still be shown. If engine load or fuel will not change, leave the scrubber seawater flow as it was when the fault started. If they will change, run the seawater flow at maximum until the analyzer works again. This is one person's opinion. Check the maker's manual and the flag and class rules before you do this.

Water level detectors

  • These detectors trip the system to stop water from flowing back into the engines. Do not disable them.
  • Keep them clean of carbon deposits. Carry a spare.

I have no readings, alarm texts or test results to give here. I can report two results: coating-only protection of the pipes failed, and the SMO sleeve was the newest fix that worked.

Comments · 0

No comments yet.

Sign in to comment, vote and confirm fixes.Sign in