When to replace a radar magnetron
Knowledge
Navigation
I replace X-band and S-band radar magnetrons on condition (magnetron current and performance tests), not on running hours alone, and I always keep a spare on board. The maker's hour interval is a…
Anonymous · 4 y
▲
0
rating
0
comments
Weishaupt Monarch burner: random "Air combustion low" at start
Troubleshooting
Boiler
·
Weishaupt Monarch
·
Air combustion low
The burner tripped only at boiler start, two or three times a day. The alarm changed: sometimes "Air combustion low", sometimes "Flame failure". It was random: no alarm for 10 hours, then up to five…
Anonymous · 4 y