Using a new bunker before the lab report arrives: precautions
EL-0148 · Procedure · rating 0 · occurred 17 Aug 2022
Source: /cases/el-0148
Scope#
When a ship has to change over to a new bunker before the lab report arrives, I treat the fuel as suspect and run with extra precautions on fuel treatment and engines until the result is known. The typical case: no other grade is left on board, so the changeover cannot wait.
This is general practice, not a confirmed fix. I have no engine maker, fuel grade or test results to give here.
Safety#
- Treat the new batch as suspect until the lab report comes in.
- Protect power generation. Keep the second (standby) diesel generator on MGO, so that if the new fuel is bad this generator can still supply power.
- Watch the main engine and diesel generators closely during this period.
Tools & parts#
- Fuel separator (purifier)
- Fuel oil filters with differential pressure indication
- MGO supply for the standby diesel generator
- On-board drain oil test kit, if the ship has one
- Contact with the fuel analysis provider
Steps#
- Before the new fuel goes into service, inspect the main engine scavenge ports. This gives a baseline condition.
- Put the standby diesel generator on MGO. Keep it on MGO until the lab report is received.
- Run the separator at minimum throughput and high temperature to get the best possible cleaning. I don't have exact flow or temperature values.
- Drain the fuel tanks often.
- Watch the fuel oil filters closely.
- If needed, shorten the separator de-sludging interval.
- If a test kit is on board, test the M/E cylinder drain oil (scavenge drain) every day. Follow the trend of the iron content. I have no limit value for it.
- Inspect the scavenge ports again a couple of days after the new fuel goes into service.
- Do this second inspection earlier if other signs appear, for example high filter differential pressure or blocked transfer pump filters.
- Ask the fuel analysis provider if they have reports of problems with fuel from the same supplier or the same bunkering area.
Check after#
- Main engine and diesel generator performance stays normal.
- Filter differential pressure and clogging rate stay normal.
- Drain oil iron content shows no rising trend.
- Scavenge port condition is the same as at the baseline inspection.
- Lab report is received and reviewed before the standby generator goes back to normal fuel.
I have no follow-up outcome to report yet.