Log inJoin

Using a new bunker before the lab report arrives: precautions

Main EnginePurifier

Contents
  1. Scope
  2. Safety
  3. Tools & parts
  4. Steps
  5. Check after
  6. Comments · 0

Scope#

When a ship has to change over to a new bunker before the lab report arrives, I treat the fuel as suspect and run with extra precautions on fuel treatment and engines until the result is known. The typical case: no other grade is left on board, so the changeover cannot wait.

This is general practice, not a confirmed fix. I have no engine maker, fuel grade or test results to give here.

Safety#

  • Treat the new batch as suspect until the lab report comes in.
  • Protect power generation. Keep the second (standby) diesel generator on MGO, so that if the new fuel is bad this generator can still supply power.
  • Watch the main engine and diesel generators closely during this period.

Tools & parts#

  • Fuel separator (purifier)
  • Fuel oil filters with differential pressure indication
  • MGO supply for the standby diesel generator
  • On-board drain oil test kit, if the ship has one
  • Contact with the fuel analysis provider

Steps#

  1. Before the new fuel goes into service, inspect the main engine scavenge ports. This gives a baseline condition.
  2. Put the standby diesel generator on MGO. Keep it on MGO until the lab report is received.
  3. Run the separator at minimum throughput and high temperature to get the best possible cleaning. I don't have exact flow or temperature values.
  4. Drain the fuel tanks often.
  5. Watch the fuel oil filters closely.
  6. If needed, shorten the separator de-sludging interval.
  7. If a test kit is on board, test the M/E cylinder drain oil (scavenge drain) every day. Follow the trend of the iron content. I have no limit value for it.
  8. Inspect the scavenge ports again a couple of days after the new fuel goes into service.
  9. Do this second inspection earlier if other signs appear, for example high filter differential pressure or blocked transfer pump filters.
  10. Ask the fuel analysis provider if they have reports of problems with fuel from the same supplier or the same bunkering area.

Check after#

  • Main engine and diesel generator performance stays normal.
  • Filter differential pressure and clogging rate stay normal.
  • Drain oil iron content shows no rising trend.
  • Scavenge port condition is the same as at the baseline inspection.
  • Lab report is received and reviewed before the standby generator goes back to normal fuel.

I have no follow-up outcome to report yet.

Comments · 0

No comments yet.

Sign in to comment, vote and confirm fixes.Sign in