Log inJoin

Wärtsilä RT-flex: liners worn out after 4000 hours, weak scavenge air

Main EngineWärtsilä RT-flex

Contents
  1. Symptoms
  2. Diagnosis
  3. Fix
  4. Result
  5. Comments · 0

Symptoms#

  • Cylinder liners failed after about 4000 running hours and had to be replaced.
  • This went on for more than 4 years.
  • Scavenge air pressure was rather low when manoeuvring.

Diagnosis#

On this engine the two auxiliary blowers must turn in opposite directions. Their casings (volutes) are made this way.

After an overhaul of one blower, its motor was connected wrongly, so the blower turned the wrong way. Nobody noticed this for more than 4 years. The fault was found by checking the rotation direction of each blower.

Fix#

Swapped two supply wires on the blower motor, so it turns in the correct direction.

Result#

After this, everything was normal.

Comments · 0

No comments yet.