Emergency generator: all alarms when the rack bracket is released

Auxiliary Engine

Notes#

After a manual (emergency) start, the fuel rack is held by a locking bracket. If this bracket is released while the engine runs, the engine stops at once and all alarms come up together.

How to stop after a manual start without alarms#

  1. Press the engine stop button first.
  2. Then release the locking bracket from the fuel rack.

Done in this order, the alarms do not come up.