MAN MC-C: no combustion in one unit, clogged ball valve at fuel pump inlet
EL-0141 · Solved · rating 0 · works for 0 engineers · occurred 20 Aug 2022
Source: /cases/el-0141
Symptoms#
Cylinder No.6 on our MAN MC-C stopped firing because the ball valve on the fuel oil inlet to its fuel pump was clogged. It took a long list of new parts before we found it.
- We reduced main engine speed from
104 rpmto100 rpm. - Soon after, a slowdown alarm came on: exhaust gas temperature deviation on cylinder No.6.
- From then on, the No.6 exhaust gas temperature read only
50 °C. The unit was not firing.
Checked#
| Check | Result |
|---|---|
| Puncture valve replaced with new one | No change |
| Suction valve replaced with new one | No change |
| Fuel valves (injectors) replaced with new ones | No change |
| Fuel pump barrel replaced with new one | No change |
| Fuel pump cover replaced with new one | No change |
| High-pressure fuel pipe replaced with new one | No change |
| Fuel pump return line | Normal |
| Fuel pump timing | Normal |
| Fuel pump roller and roller gear | Normal |
| Exhaust valve | Opened up, found in good condition |
| Scavenge space | Clean of fuel. Some unburnt cylinder oil was seen |
| Whole No.6 fuel pump fitted on unit No.1 | Unit No.1 ran normally. No.6 still did not fire |
Other checks worth making on the unit in a case like this:
- Fuel pump rack position. Is it different from the other units?
- VIT.
- Non-return valves in the fuel oil return line.
- High-pressure pipes from pump to injectors: tightening torque and collar/nut distances.
I have no record of whether these were done.
Diagnosis#
The pump swap was the key test. The No.6 pump worked well on unit No.1, so the pump was good and the fault was in the No.6 position itself.
Two days later I found the cause: the ball valve on the fuel oil inlet to the No.6 fuel pump was clogged. The pump got no fuel, so the cylinder could not fire.
I don't know why the valve clogged, or why the problem started when we reduced the speed.
Lesson: before you replace expensive pump and injector parts, first make sure fuel reaches the pump. A pump swap between units quickly shows if the fault is in the pump or in the unit position.
Fix#
- Stop the engine. Isolate and drain the fuel supply to the affected pump before you open anything.
- Find the ball valve on the fuel oil inlet to that pump.
- Check that fuel can pass through it. Here it was clogged.
- Clear the blockage. I have no record of whether it was cleaned or replaced.
Result#
I have no record of the final result after the fix.
Comments · 0
No comments yet.