MAN MC-C: no combustion in one unit, clogged ball valve at fuel pump inlet

Main EngineMAN B&W MC-CSlowdown: exhaust gas temperature deviation, cylinder No.6

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Result
  6. Comments · 0

Symptoms#

Cylinder No.6 on our MAN MC-C stopped firing because the ball valve on the fuel oil inlet to its fuel pump was clogged. It took a long list of new parts before we found it.

  • We reduced main engine speed from 104 rpm to 100 rpm.
  • Soon after, a slowdown alarm came on: exhaust gas temperature deviation on cylinder No.6.
  • From then on, the No.6 exhaust gas temperature read only 50 °C. The unit was not firing.

Checked#

CheckResult
Puncture valve replaced with new oneNo change
Suction valve replaced with new oneNo change
Fuel valves (injectors) replaced with new onesNo change
Fuel pump barrel replaced with new oneNo change
Fuel pump cover replaced with new oneNo change
High-pressure fuel pipe replaced with new oneNo change
Fuel pump return lineNormal
Fuel pump timingNormal
Fuel pump roller and roller gearNormal
Exhaust valveOpened up, found in good condition
Scavenge spaceClean of fuel. Some unburnt cylinder oil was seen
Whole No.6 fuel pump fitted on unit No.1Unit No.1 ran normally. No.6 still did not fire

Other checks worth making on the unit in a case like this:

  • Fuel pump rack position. Is it different from the other units?
  • VIT.
  • Non-return valves in the fuel oil return line.
  • High-pressure pipes from pump to injectors: tightening torque and collar/nut distances.

I have no record of whether these were done.

Diagnosis#

The pump swap was the key test. The No.6 pump worked well on unit No.1, so the pump was good and the fault was in the No.6 position itself.

Two days later I found the cause: the ball valve on the fuel oil inlet to the No.6 fuel pump was clogged. The pump got no fuel, so the cylinder could not fire.

I don't know why the valve clogged, or why the problem started when we reduced the speed.

Lesson: before you replace expensive pump and injector parts, first make sure fuel reaches the pump. A pump swap between units quickly shows if the fault is in the pump or in the unit position.

Fix#

  1. Stop the engine. Isolate and drain the fuel supply to the affected pump before you open anything.
  2. Find the ball valve on the fuel oil inlet to that pump.
  3. Check that fuel can pass through it. Here it was clogged.
  4. Clear the blockage. I have no record of whether it was cleaned or replaced.

Result#

I have no record of the final result after the fix.

Comments · 0

No comments yet.

Sign in to comment, vote and confirm fixes.Sign in