▲0 rating0 commentsAlfa Laval SA820: "Sludge in bowl" alarm every day or two after overhaulTroubleshootingPurifier · Alfa Laval SA820 · Sludge in bowlAfter an overhaul the separator ran normally for several days. Then the "Sludge in bowl" alarm came every one or two days. The separator had tried to calibrate itself and could not close the bowl.Anonymous · 5 y▲0 rating0 commentsAtlas incinerator will not burn sludge: no start signal to dosing pumpTroubleshootingIncinerator & Sewage · AtlasThe incinerator would not burn sludge. Chamber temperature rose normally and reached the set point for starting the sludge burner. But the PLC gave no output signals: no "dosing pump ready to start",…Anonymous · 6 y▲0 rating0 commentsWestfalia OSD 18: weak sludge discharge when hydrophore pressure is lowTroubleshootingPurifier · Westfalia OSD 18Poor sludge discharge: no normal "bang", the bowl only "sneezes" and little comes out. Everything else worked correctly. With the hydrophore at 5.1–5.6 bar the discharge was normal. At 4.3 bar the…Anonymous · 4 y▲0 rating0 commentsShipboard incinerator: how to keep it in good conditionKnowledgeIncinerator & SewageKeeping a shipboard incinerator in good condition mostly means clean air inlets and burner parts, a slow shutdown, careful sludge handling and sensible loading. These are the practices I follow,…Anonymous · 4 y▲0 rating0 commentsMain engine EGR: deposits and wear depend mainly on fuel sulphurKnowledgeMain EngineOn a two-stroke main engine EGR (exhaust gas recirculation) system, fuel sulphur content is the main factor behind deposits in the air cooler and scavenge receiver and the amount of drain water and…Anonymous · 4 y▲0 rating0 commentsBunker fuel quality: ISO 8217 fuel can still cause engine problemsKnowledgeMain EngineThese are my general notes about bunker fuel quality. They do not describe a real fault on a ship. I give no engine maker, no readings and no test results. I wrote them in two parts. Main point…Anonymous · 2 y▲0 rating0 commentsFuel oil purifiers: how to remove more cat finesKnowledgePurifierTo remove more catalytic fines (cat fines), fuel oil purifiers (centrifugal separators) need low throughput, the right temperature and good maintenance. These are my general notes; there is no…Anonymous · 4 y▲0 rating0 commentsMAN B&W ES main engine: precautions for long low-load runningKnowledgeMain Engine · MAN B&W ESMAN Service Letter SL09-511/MTS gives 10% load as the lowest load for continuous running of a MAN B&W ES two-stroke main engine, and running in this range needs precautions. These are the precautions…Anonymous · 4 y▲0 rating0 commentsAlfa Laval SA805 lube oil separator: bowl opens by itself after about 10 hoursTroubleshootingPurifier · Alfa Laval SA805 · Low back pressureThe separator ran for about 10 hours, then the bowl opened by itself. The closing water went to the drain, and nothing held the bowl closed. Alarm: "Low back pressure". The other two separators…Anonymous · 4 y