LNG dual-fuel ship: how the fuel gas supply system works
EL-0162 · Knowledge · rating 0 · occurred 07 Apr 2023
Source: /cases/el-0162
Notes#
The fuel gas supply system (FGSS) on an LNG dual-fuel ship controls boil-off gas pressure in the LNG fuel tanks and turns LNG into gas for the engines and boilers; its design is set mainly by the type of dual-fuel main engine. This is a general description of the system, not a case from a real ship.
What the system does
- It keeps the boil-off gas (BOG) pressure in the LNG fuel tanks under control.
- It vaporises and warms LNG and sends it as gas to the main engine, the auxiliary engines and the boilers.
- Design follows the IGF Code and the class rules. I don't cover any other standard here.
Main engine type sets the design
The owner chooses the dual-fuel main engine. This choice sets how the gas is handled:
| Main engine cycle | Gas supply | Approx. gas pressure |
|---|---|---|
| Diesel cycle | High-pressure gas injection | about 300 bar |
| Otto cycle | Low-pressure gas admission | about 15 bar |
- Auxiliary engines and boilers usually take low-pressure gas, below
5 bar. - Auxiliary boilers may also use BOG directly from the tanks. No pump or compressor is needed for this. The gas pressure is very low.
Main components
- Glycol-water heating loop. A closed circuit with a steam heater and 2 circulating pumps. It supplies heat to the HP and LP vaporizers.
- HP and LP vaporizers. Heat exchangers. Glycol-water warms the LNG in them when heating is needed.
- LP LNG supply pumps. In most designs they sit in the LNG inside the tanks. They feed the fuel handling equipment and the LP consumers (auxiliary engines, boilers).
- HP LNG pumps. They raise the pressure to about
300 barfor a Diesel-cycle main engine with HP gas injection. - BOG compressor. It sends BOG to the main engine and the auxiliaries. It can work in HP mode or LP mode.
- A central control system for the whole FGSS.
- Safety devices and automation as required by the IGF Code.
- Nitrogen generators. Nitrogen purges and inerts the tanks, the components and the piping. This keeps gas concentrations at a safe level when the gas supply is stopped.
Layout
- Most of the FGSS equipment is in a separate fuel gas preparation room. This room is built to the IGF Code and class rules.
- The nitrogen generators are not in this room.
What this note doesn't cover
- Pressures here are approximate figures only.
- No temperatures, makers or models, alarm or trip setpoints, operating or changeover procedures, maintenance intervals, or real fault experience. I check the ship's own FGSS manuals and class documents for actual values and procedures.
Comments · 0