Log inJoin

LNG dual-fuel ship: how the fuel gas supply system works

Main EngineAuxiliary Engine

Notes#

The fuel gas supply system (FGSS) on an LNG dual-fuel ship controls boil-off gas pressure in the LNG fuel tanks and turns LNG into gas for the engines and boilers; its design is set mainly by the type of dual-fuel main engine. This is a general description of the system, not a case from a real ship.

What the system does

  • It keeps the boil-off gas (BOG) pressure in the LNG fuel tanks under control.
  • It vaporises and warms LNG and sends it as gas to the main engine, the auxiliary engines and the boilers.
  • Design follows the IGF Code and the class rules. I don't cover any other standard here.

Main engine type sets the design

The owner chooses the dual-fuel main engine. This choice sets how the gas is handled:

Main engine cycleGas supplyApprox. gas pressure
Diesel cycleHigh-pressure gas injectionabout 300 bar
Otto cycleLow-pressure gas admissionabout 15 bar
  • Auxiliary engines and boilers usually take low-pressure gas, below 5 bar.
  • Auxiliary boilers may also use BOG directly from the tanks. No pump or compressor is needed for this. The gas pressure is very low.

Main components

  1. Glycol-water heating loop. A closed circuit with a steam heater and 2 circulating pumps. It supplies heat to the HP and LP vaporizers.
  2. HP and LP vaporizers. Heat exchangers. Glycol-water warms the LNG in them when heating is needed.
  3. LP LNG supply pumps. In most designs they sit in the LNG inside the tanks. They feed the fuel handling equipment and the LP consumers (auxiliary engines, boilers).
  4. HP LNG pumps. They raise the pressure to about 300 bar for a Diesel-cycle main engine with HP gas injection.
  5. BOG compressor. It sends BOG to the main engine and the auxiliaries. It can work in HP mode or LP mode.
  6. A central control system for the whole FGSS.
  7. Safety devices and automation as required by the IGF Code.
  8. Nitrogen generators. Nitrogen purges and inerts the tanks, the components and the piping. This keeps gas concentrations at a safe level when the gas supply is stopped.

Layout

  • Most of the FGSS equipment is in a separate fuel gas preparation room. This room is built to the IGF Code and class rules.
  • The nitrogen generators are not in this room.

What this note doesn't cover

  • Pressures here are approximate figures only.
  • No temperatures, makers or models, alarm or trip setpoints, operating or changeover procedures, maintenance intervals, or real fault experience. I check the ship's own FGSS manuals and class documents for actual values and procedures.

Comments · 0

No comments yet.

Sign in to comment, vote and confirm fixes.Sign in