MAN ME-C: running with one HPS pump in fail mode
EL-0167 · Knowledge · rating 0 · occurred 04 Jan 2023
Source: /cases/el-0167
Notes#
With one of three HPS pumps in "fail", an ME-C main engine can usually keep full function if the fault is only electronic or in the cables; a mechanical fault is a different case. These are my notes on how I judge it.
Equipment. An electronically controlled MAN Energy Solutions ME-C main engine. The hydraulic power supply (HPS) has three pumps, with both engine-driven and electric-driven pumps.
Electronic or cable fault
- The engine can keep full function, even with just one of the three pumps working.
- Example: a faulty proportional valve. When control of the pump is lost this way, the pump itself pushes the swash plate to full AHEAD (
100%). This is done mechanically and hydraulically, not by the control system.
Mechanical fault
- The above does not hold for a mechanical fault inside the failed engine-driven pump, or in the equipment that supports that pump.
What to watch
- Trouble is more likely during manoeuvring, and more so when running astern at low load and low RPM. The electric-driven pumps may then start to help, and low hydraulic pressure alarms may appear.
- The integrity of the whole hydraulic system matters a lot.
- With two pumps in service, the system may run normally in most cases.
What this note doesn't cover
- This is general guidance, not a reported repair. I have no pressure values, alarm setpoints, ship name or exact engine model here.
- What the actual fault was, or how it was fixed.
Comments · 0