Log inJoin

MAN B&W ME: HPS pressure build-up time and decay check

Main EngineMAN B&W ME

Notes#

On a MAN B&W ME engine with one start-up pump running, I take an HPS pressure build-up time under 30 s as acceptable, and I also check the pressure decay time. The full maker requirements are in the MAN B&W Accumulator Handbook.

Maker documents

  • The MAN B&W Accumulator Handbook holds the full build-up time requirements. It can be downloaded free from the MAN website. I don't quote a figure from it here.
  • The "Troubleshooting guide for ME hydraulic system" (PDF) is the other document I use for this.

Practical figures

  • Example set point: 225 bar at standstill, for a 300 bar system.
  • With one electric pump and no leaks, the time from 0 bar to set point can sometimes be under 15 s.
  • As a general rule, a build-up time under 30 s is acceptable.
  • To judge the integrity of the hydraulic system, I also monitor and measure the pressure decay time. I have no limit for decay time.

Limits of these figures

  • The 15 s and 30 s figures are practical experience, not quoted maker values.
  • For official values, check the MAN B&W Accumulator Handbook and the engine instruction book.
  • What this note doesn't cover: engine model, bore, pump make and measured times. No actual fault is described.