MAN B&W ME: HPS pressure build-up time and decay check
EL-0171 · Knowledge · rating 0 · occurred 26 May 2023
Source: /cases/el-0171
Notes#
On a MAN B&W ME engine with one start-up pump running, I take an HPS pressure build-up time under 30 s as acceptable, and I also check the pressure decay time. The full maker requirements are in the MAN B&W Accumulator Handbook.
Maker documents
- The MAN B&W Accumulator Handbook holds the full build-up time requirements. It can be downloaded free from the MAN website. I don't quote a figure from it here.
- The "Troubleshooting guide for ME hydraulic system" (PDF) is the other document I use for this.
Practical figures
- Example set point:
225 barat standstill, for a300 barsystem. - With one electric pump and no leaks, the time from
0 barto set point can sometimes be under15 s. - As a general rule, a build-up time under
30 sis acceptable. - To judge the integrity of the hydraulic system, I also monitor and measure the pressure decay time. I have no limit for decay time.
Limits of these figures
- The
15 sand30 sfigures are practical experience, not quoted maker values. - For official values, check the MAN B&W Accumulator Handbook and the engine instruction book.
- What this note doesn't cover: engine model, bore, pump make and measured times. No actual fault is described.