How to take one cylinder out of service on MAN ME-C
EL-0174 · Procedure · rating 0 · occurred 23 Jun 2022
Source: /cases/el-0174
Scope#
To take one cylinder unit out of operation on an ME-C (electronically controlled 2-stroke) main engine, I set the Chief Index limit for that cylinder to 0 on the MOP. This is an outline only. The full procedure is in the M/E instruction manual, in the chapter "How to take a cylinder unit out of operation". Read that chapter before you start.
What this note doesn't cover
- HCU (hydraulic cylinder unit) isolation, locking the exhaust valve open or closed, and the starting air valve.
- Cylinder lube oil (Alpha lubricator) settings for the isolated unit, and whether to lift the fuel pump or plunger.
- Allowed load or rpm with one cylinder cut out, actual barred speed values, and the alarms and MOP values that appear when a cylinder is cut out.
- Any maker service letter.
Safety#
- With one cylinder out of operation, the engine has an extra barred speed range. This range is not given in the M/E manual. Look for it in the torsional vibration calculation for the engine.
- Tell the Master and the Chief Engineer about this extra range, so that the engine is not run in it.
- Follow the maker's manual for all steps that this note does not cover.
Tools & parts#
- MOP (Main Operating Panel)
- M/E instruction manual
- Torsional vibration calculation for the engine
Steps#
- Read the M/E manual chapter "How to take a cylinder unit out of operation".
- On the MOP, open the Chief Limiters screen. On these engines, in an emergency, this is the only place where the fuel booster of one cylinder can be isolated.
- Set the Chief Index limit for that cylinder to
0. With this setting, the cylinder has no combustion. - Decide what to do with the exhaust valve of that unit. It is usually left working, so that the engine stays partly balanced. This is not always the right choice: sometimes the exhaust valve has to be switched to "Disabled" and held in a locked position, either open or closed. I can't say which cases need this; follow the manual.
- Find the extra barred speed range for running with one cylinder out, in the torsional vibration calculation.
- Inform the Master and the Chief Engineer of this range.
Check after#
- Check on the MOP that the Chief Index limit for the isolated cylinder shows
0. - Check that the exhaust valve of the unit is in the state you chose (working, or locked open or closed).
- Make sure the engine does not run in the extra barred speed range.
Still open: the alarms and MOP values to expect with a cylinder cut out, and the maximum engine load with one cylinder off for each engine type and cylinder number.