Log inJoin

Main engine EGR: deposits and wear depend mainly on fuel sulphur

Main Engine

Notes#

On a two-stroke main engine EGR (exhaust gas recirculation) system, fuel sulphur content is the main factor behind deposits in the air cooler and scavenge receiver and the amount of drain water and sludge. These are my notes on deposits, liner, crown and ring wear, and drain and sludge handling.

My experience

  • My experience with the M/E EGR system has been good so far. I have no specific failure to report.
  • Fuel sulphur content decides how many deposits form and how much EGR drain water and sludge the system makes.
  • EGR systems are designed for different fuels. Some are for low-sulphur fuel (MGO with 0.1% S). Others are for higher-sulphur fuel (0.5% S, or even 3.5% S). Ask the maker which fuel your installed system is designed for.
  • With high-sulphur fuel, expect more deposits and more drain water and sludge. The EGR water treatment system must be sized and specified for the sulphur level of the fuel you really burn.
  • Liner, crown and ring problems are hard to link to EGR operation alone.
  • A common root cause of EGR problems is that the system stands idle for long periods, because it is used only inside NECA (NOx Emission Control Area) zones.

Practices I follow

As far as practicable:

  1. Inspect the M/E scavenge space often. Measure the cermet coating on the piston rings.
  2. Clean the scavenge space often. Clear any blocked scavenge drain pipes.
  3. Send M/E scrape-down oil samples to a shore laboratory for analysis often.
  4. Check the EGR system as described in MAN service letter SL2020-699. Because of this reference the note probably applies to MAN B&W engines, but I have not named a maker or model here.

What this note doesn't cover

  • Amounts of deposits, inspection and cleaning intervals, and limits for the ring coating.
  • Methods or chemicals for treating drains and sludge, and sludge disposal. On drains and sludge my only general rule is: match the treatment system to the fuel.
  • Any real damage case, and the content of SL2020-699.