How to inspect the scavenge space on a two-stroke main engine

Main EngineMAN ES

Contents
  1. Scope
  2. Safety
  3. Tools & parts
  4. Steps
  5. Check after
  6. Comments · 0

Scope#

This is how I do a scavenge space inspection on a 2-stroke main engine through the scavenge ports in the liner, plus the checks I make for water carry-over.

Inspect often. Regular checks let you see corrosive, abrasive or adhesive wear at an early stage, so you can look for the root cause.

I give no numbers for limits here. Compare ring clearance, liner groove size and coating thickness with the maker's values.

Safety#

I do not list safety steps here. Follow the ship's own rules and the maker's manual for opening and entering the scavenge space.

Note: in my method the main LO pumps stay running during the inspection.

The engine must be turned to bring each piston to BDC. Follow the ship's rules for the turning gear. Make sure nobody has hands or tools in the ports while the engine turns.

Tools & parts#

  • Feeler gauge
  • Flashlight
  • Vernier gauge, for the liner grooves
  • Small camera that fits through the scavenge ports
  • Pencil, marker or chalk
  • Mallet (wooden handle is better) or a bronze bar
  • Screwdriver, for the non-return flaps on the air intake
  • Mirror on a telescopic handle
  • Clean rags
  • Elcometer, for rings with a cermet coating

Steps#

  1. Do not clean first. Inspect the scavenge space in its dirty state. The main LO pumps stay on.
  2. Use the feeler gauge to measure each ring's clearance in its groove. Compare with the maker's values.
  3. Where you can reach them, measure the liner grooves with the vernier gauge. Compare with the maker's values.
  4. Use the mallet or bronze bar on the rings to check that they move and are not stuck.
  5. Use the screwdriver to check the scavenge non-return valves (flaps).
  6. Look at the carbon deposits on the piston crown top and on the ring lands.
  7. Check each ring's running surface for seizure marks, cracks, broken or missing pieces, and for too much or too little oil. To judge the oil, clean one port with a rag and leave the rest as they are. Take close-up photos.
  8. On rings with a cermet coating, clean the running face and measure the coating with the Elcometer. Compare with the maker's values.
  9. Look at the piston crown top for traces of water, fuel or LO. Check the piston skirt. Look for system oil leaking from the piston crown studs.
  10. With the piston at BDC, check the liner running surface for wave-cut marks, seizure, polishing and corrosion.
  11. Record the results on the report forms from the maker's manual. For every unit, attach a good set of clear photos.
  12. After the inspection, clean the scavenge space. Clear any blocked scavenge drain pipes.

Check after#

Water carry-over

  • In my view, the 2020 sulphur cap is a large part of the reason liner wear has increased.
  • Check that water drains away. Look at the water mist catcher (WMC) and the air cooler. Valves A and H must be fully open, as shown on the MAN ES instruction plate.
  • Check the WMC fitting. Drain valves have been found only half open. Some WMCs were fitted with no gap, so water could not leave the engine (MAN SL2011-542).
  • About 80% of the condensed water is removed at the pre-catcher, and about 15% at the WMC.
  • Signs of water carry-over:
    • small yellow or brown rust spots on the piston rods
    • more wear at the lower part of the liner
    • too much water in the cylinder can break the oil film
  • Run with the lowest scavenge air temperature you can, and in any case below 45 °C (MAN SL2014-589). The water separator works better at a lower temperature.

How much condensate to expect (worked example from the MAN ES operation manual):

ItemValue
Engine7K80MC-C at 22,700 kW
Ambient air30 °C, 85% RH
Scavenge air3.25 bar abs, 45 °C
Water in ambient air (chart)0.21 kg/kWh
Water in scavenge air (chart)0.17 kg/kWh
Factor k1.05

Condensate = k x load x (ambient water − scavenge water) = 1.05 x 22,700 x 0.04 = about 953 kg/h. Take it as about 950 kg/h ±10%, or about 22.8 t/day.

  • k is 1.05 for K80–K98, 1.00 for S50–S90 and L50–L70, 0.90 for S26–S46 and L35–L42.
  • A negative result means no water condenses.
  • Sea water temperature can be used in place of ambient temperature. In that case use the 100% RH curve.
  • The method assumes nominal air flow and an even outlet temperature from the air cooler. When the difference is small (between -0.01 and 0.01 kg/kWh), the result is only rough guidance.

MAN also has a document on cylinder condition inspection, with photos and examples, and I use a sample inspection report. Their content is not included here.

Comments · 0

No comments yet.

Sign in to comment, vote and confirm fixes.Sign in