▲0 rating0 commentsDiesel oil bunkering: tank overflow through a taped vent, engine room fire (Stride)IncidentBoiler · MAN B&W 7S70MC Mk6 · Diesel oil seen dripping from upper ER; no tank high-level alarm recordedGeneral cargo ship alongside at LaPorte, Texas, taking 80 mt of LSMGO into the port and starboard double-bottom DO tanks. The C/E and 3/E ran the bunkering from the ECR, with both fill valves open.…Anonymous · 1 y▲0 rating0 commentsSEA-Mate B500 blender stops after blending, blend not dischargedTroubleshootingMain Engine · Marine Fluid Technology SEA-Mate Blender B500In auto mode the unit mixes the oils, then stops and stays stopped. It should open the valve and pump the blend on, but it does not. No alarm.Anonymous · 3 y▲0 rating0 commentsScrubber: "CEMS failure" alarm every 4 minutes, no alarm on the SICK analyserTroubleshootingOther · SICK CEMS · CEMS failureThe scrubber panel shows "CEMS failure" about every 4 minutes. Sometimes there is no alarm for about 20 minutes, then it comes back. The CEMS itself shows no new alarm. Its status goes to Stop and…Anonymous · 3 y▲0 rating0 commentsBoll & Kirch filter turns back to the dirty chamber at flushingTroubleshootingOther · Boll & Kirch 6.72, BK 2200 controllerAt backflushing: The solenoid worked and the filter turned to the clean chamber. The solenoid switched off, air was cut, and the filter turned back to the dirty chamber. This happened twice in a row.…Anonymous · 5 y▲0 rating0 commentsHyundai lift works only in Manual or Inspection mode, not in Auto, no alarmTroubleshootingOther · Hyundai ElevatorIn heavy pitching, the ship slammed into a wave with strong vibration. The lift stopped at that moment. The car was brought down in Manual mode and the breaker was switched off. After switching on…Anonymous · 6 y