▲0 rating0 commentsTMC Tamrotor screw compressor: "R:3137 RUN INHIBIT", "check pressure in pipe"TroubleshootingCompressed Air · TMC Tamrotor EMH 21-44 · R:3137 RUN INHIBITThe display showed 6.0 bar and "R:3137 RUN INHIBIT". The manual has only two alarms marked R. For them it says: "check pressure in pipe".Anonymous · 1 y▲0 rating0 commentsIncinerator will not light: thick white smoke, flame sensor drops outTroubleshootingIncinerator & SewageThe incinerator would not light. The flame sensor lost the flame. Before, it had worked every day. The furnace had not been cleaned for a long time. Both chambers were full of ash, and all the air…Anonymous · 3 y▲0 rating0 commentsDiesel oil bunkering: tank overflow through a taped vent, engine room fire (Stride)IncidentBoiler · MAN B&W 7S70MC Mk6 · Diesel oil seen dripping from upper ER; no tank high-level alarm recordedGeneral cargo ship alongside at LaPorte, Texas, taking 80 mt of LSMGO into the port and starboard double-bottom DO tanks. The C/E and 3/E ran the bunkering from the ECR, with both fill valves open.…Anonymous · 1 y▲0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y