0 rating0 commentsFire detection: fault on loop point 2.6, but all loop detectors test OKTroubleshootingFire & SafetyThe fire detection panel showed a fault on loop 2, point 2.6. The ship was in a storm.Anonymous · 6 y0 rating0 commentsControl room console: lamp test, duty engineer call and phone horn all deadTroubleshootingElectricalSeveral functions of the engine control room console stopped at the same time: Lamp test did not work. Duty engineer call did not work. When the engine room telephone rang, the loud horn in the…Anonymous · 7 y0 rating0 commentsRolls-Royce steering gear: one pump stops the rudder at 10° to one sideTroubleshootingSteering Gear · Rolls-RoyceWith one of the two pumps, the rudder would not go more than 10° to one side. Same in follow-up and non-follow-up. It stopped at exactly 10° every time, from any starting position. Pushing the…Anonymous · 7 y0 rating0 commentsEngine room fire: fuel backflow through an open return line (Scot Stuttgart)IncidentAuxiliary Engine · "" · ER fire alarm, thick white smoke in port ERChemical tanker with two engine rooms, alongside in San Juan discharging cargo. The port AE was under LOTO for turbocharger and aftercooler cleaning. The crew removed the aftercooler and the fuel…Anonymous · 2 mo