comments
Aux boiler explosion: waxy MGO, then fan restart into a gassy furnace (Manhattan Bridge)
Incident
Boiler
·
""
·
Aux boiler emergency trip (Furnace flame-eye abnormal)
A 13,900 TEU container ship was berthing at Felixstowe in winter. The auxiliary boiler (rotary cup burner) had been on MGO for three days for the ECA. It tripped four times between 17:30 and 19:51.…
Anonymous · 8 y
▲
0
rating
0
comments
Cummins NTA855 emergency generator: speed hunts ±30 rpm after a cold start
Troubleshooting
Auxiliary Engine
·
Cummins NTA855-D(M)
On the first cold start, speed hunted by about ±30 rpm at 1800 rpm (frequency by about 0.5 Hz). After a restart (sometimes the 2nd or 3rd) it ran smoothly, and further starts were fine. A few hours…
Anonymous · 1 y
▲
0
rating
0
comments
Fatal engine room fire after opening a pressurised fuel filter (Moritz Schulte)
Incident
Auxiliary Engine
·
MAN B&W L23/30H
·
ER fire alarm
LPG carrier discharging alongside in Antwerp. AE2 and AE3 were running and AE1 was on standby. After the morning toolbox talk the newly promoted 3/E asked the 2/E if he could clean the AE1 fuel…
Anonymous · 3 y