Main switchboard low insulation: find the fault by isolating loads
Procedure
Electrical
·
Low insulation
This is how I find the cause of a low insulation alarm or low reading on the main switchboard (MSB): isolate all loads, then reconnect them one at a time while watching the insulation monitor. It…
Anonymous · 4 y
▲
0
rating
0
comments
Switchboard earth lamps do not light, only one of three on lamp test
Troubleshooting
Electrical
The insulation resistance monitor (IRM) worked normally. The earth lamps did not light. With the test button pressed, only one of the three lamps lit.
Anonymous · 3 mo
▲
0
rating
0
comments
Emergency generator: insulation drops to 0.1 MΩ at every start
Troubleshooting
Electrical
·
Low insulation 440 V
Every time the emergency generator started, the 440 V insulation monitor fell to 0.1–0.2 MΩ. After 2–3 hours of running, the reading slowly came back to normal (5 MΩ and higher). The ship had been…
Anonymous · 7 y