Search
Cases
Search cases
Clear
⌘K
All
10
Solved
5
Open
0
Troubleshooting
Incident analysis
Procedure
Knowledge
5 cases match
Equipment
All
Main Engine
Auxiliary Engine
Turbocharger
Boiler
Purifier
Compressed Air
Pumps
Fresh Water Generator
OWS & Bilge
Incinerator & Sewage
Refrigeration & HVAC
Steering Gear
Propulsion & Thrusters
Deck Machinery
Ballast System
Electrical
Automation / PLC
Navigation
Fire & Safety
Other
Sort
Best match
Newest first
Highest rated
Most confirmed
Recently updated
Apply
▲
0
rating
0
comments
Aux boiler explosion: waxy MGO, then fan restart into a gassy furnace (Manhattan Bridge)
Incident
Boiler
·
""
·
Aux boiler emergency trip (Furnace flame-eye abnormal)
A 13,900 TEU container ship was berthing at Felixstowe in winter. The auxiliary boiler (rotary cup burner) had been on MGO for three days for the ECA. It tripped four times between 17:30 and 19:51.…
Anonymous · 8 y
▲
0
rating
0
comments
IMO fuel supply pump gives only 5 bar on diesel oil
Troubleshooting
Pumps
·
IMO
The fuel supply pumps (IMO screw pumps) gave only about 5 bar when running on diesel oil. The ship rarely ran on diesel, so the fault went unnoticed for a long time. It took three months to find.
Anonymous · 2 y
▲
0
rating
0
comments
ACONIS AMS: diesel tanks show level, but volume does not change
Troubleshooting
Automation / PLC
·
Hyundai ACONIS
On the ACONIS "Tank overview" page, the MGO (diesel oil) tanks showed the level correctly. The volume in m³ did not change when the level changed. Example: MGO storage tank (P) 10.64 m level showed…
Anonymous · 5 y
▲
0
rating
0
comments
Fatal engine room fire after opening a pressurised fuel filter (Moritz Schulte)
Incident
Auxiliary Engine
·
MAN B&W L23/30H
·
ER fire alarm
LPG carrier discharging alongside in Antwerp. AE2 and AE3 were running and AE1 was on standby. After the morning toolbox talk the newly promoted 3/E asked the 2/E if he could clean the AE1 fuel…
Anonymous · 3 y
▲
0
rating
0
comments
Aalborg thermal oil boiler: no fuel from the nozzle at ignition
Troubleshooting
Boiler
·
Aalborg, LAL burner control
After a safety alarm test the boiler stopped and did not start again. The coil of the recirculation (return) solenoid valve had burnt. It had run hot for a long time: it looked melted and its wiring…
Anonymous · 1 y
EngineLog
Home
Cases
Assistant
Library
Log in
Join
Home
Cases
Assistant
Library