HFO to MGO changeover: cool slowly and watch viscosity
Procedure
Main Engine
Changing the main engine and diesel generators from HFO to MGO is safe if fuel temperature falls slowly and viscosity stays between 2 cSt and 20 cSt. This is the general procedure I use; it follows…
Anonymous · 3 y
▲
0
rating
0
comments
Aux boiler explosion: waxy MGO, then fan restart into a gassy furnace (Manhattan Bridge)
Incident
Boiler
·
""
·
Aux boiler emergency trip (Furnace flame-eye abnormal)
A 13,900 TEU container ship was berthing at Felixstowe in winter. The auxiliary boiler (rotary cup burner) had been on MGO for three days for the ECA. It tripped four times between 17:30 and 19:51.…
Anonymous · 8 y
▲
0
rating
0
comments
Fuel treatment chemicals: why engine makers prefer good fuel management
Knowledge
Main Engine
The big makers of main and generator engines prefer good fuel management to fuel treatment chemicals; they have not confirmed the claimed benefits of additives. The one exception I make is a…
Anonymous · 4 y
▲
0
rating
0
comments
IMO fuel supply pump gives only 5 bar on diesel oil
Troubleshooting
Pumps
·
IMO
The fuel supply pumps (IMO screw pumps) gave only about 5 bar when running on diesel oil. The ship rarely ran on diesel, so the fault went unnoticed for a long time. It took three months to find.
Anonymous · 2 y
▲
0
rating
0
comments
ACONIS AMS: diesel tanks show level, but volume does not change
Troubleshooting
Automation / PLC
·
Hyundai ACONIS
On the ACONIS "Tank overview" page, the MGO (diesel oil) tanks showed the level correctly. The volume in m³ did not change when the level changed. Example: MGO storage tank (P) 10.64 m level showed…
Anonymous · 5 y
▲
0
rating
0
comments
Using a new bunker before the lab report arrives: precautions
Procedure
Main Engine
When a ship has to change over to a new bunker before the lab report arrives, I treat the fuel as suspect and run with extra precautions on fuel treatment and engines until the result is known. The…
Anonymous · 4 y
▲
0
rating
0
comments
Fatal engine room fire after opening a pressurised fuel filter (Moritz Schulte)
Incident
Auxiliary Engine
·
MAN B&W L23/30H
·
ER fire alarm
LPG carrier discharging alongside in Antwerp. AE2 and AE3 were running and AE1 was on standby. After the morning toolbox talk the newly promoted 3/E asked the 2/E if he could clean the AE1 fuel…
Anonymous · 3 y
▲
0
rating
0
comments
Aalborg thermal oil boiler: no fuel from the nozzle at ignition
Troubleshooting
Boiler
·
Aalborg, LAL burner control
After a safety alarm test the boiler stopped and did not start again. The coil of the recirculation (return) solenoid valve had burnt. It had run hot for a long time: it looked melted and its wiring…
Anonymous · 1 y
▲
0
rating
0
comments
Bunker fuel quality: ISO 8217 fuel can still cause engine problems
Knowledge
Main Engine
These are my general notes about bunker fuel quality. They do not describe a real fault on a ship. I give no engine maker, no readings and no test results. I wrote them in two parts. Main point…
Anonymous · 2 y
▲
0
rating
0
comments
Main engine EGR: deposits and wear depend mainly on fuel sulphur
Knowledge
Main Engine
On a two-stroke main engine EGR (exhaust gas recirculation) system, fuel sulphur content is the main factor behind deposits in the air cooler and scavenge receiver and the amount of drain water and…
Anonymous · 4 y