▲0 rating0 commentsMAN ME: internal leak test on the hydraulic systemProcedureMain Engine · MAN ES ME-type main engineThis procedure is for MAN ES main engines with electronic control (ME type). It covers the hydraulic power supply (HPS) pumps, the hydraulic cylinder units (HCU) and the safety and accumulator block.…Anonymous · 4 y▲0 rating0 commentsMAN B&W ME: HPS pressure build-up time and decay checkKnowledgeMain Engine · MAN B&W MEOn a MAN B&W ME engine with one start-up pump running, I take an HPS pressure build-up time under 30 s as acceptable, and I also check the pressure decay time. The full maker requirements are in the…Anonymous · 3 y▲0 rating0 commentsMAN 6S50ME-C: unit loses compression 10 minutes after overhaulTroubleshootingMain Engine · MAN B&W 6S50ME-CUnit 1 of the main engine was overhauled. Tests in port were normal. About 10 minutes after leaving port, the unit started knocking and lost compression. After a restart the unit worked again, but…Anonymous · 4 y▲0 rating0 commentsMAN ME-C: running with one HPS pump in fail modeKnowledgeMain Engine · MAN Energy Solutions ME-CWith one of three HPS pumps in "fail", an ME-C main engine can usually keep full function if the fault is only electronic or in the cables; a mechanical fault is a different case. These are my notes…Anonymous · 3 y▲0 rating0 commentsMAN B&W ME: how cylinder prelubrication before start worksKnowledgeMain Engine · MAN B&W MEBackground The engine is a MAN B&W ME-type two-stroke main engine with Alpha cylinder lubricators. The ME hydraulic system pressure drives the lubricators. From the MOP (Main Operating Panel), the…Anonymous · 1 y▲0 rating0 commentsBallast valve remote control: half the valves stop responding, no alarmTroubleshootingBallast System · Utsuki valve remote control, Yokogawa FA-M3 PLCAbout half of the hydraulic ballast valves stopped responding, all at the same time. No reaction from the ballast console or from the local control panel. No alarms. The valves could still be moved…Anonymous · 6 y▲0 rating0 commentsHyundai steering gear: pump stops 4 seconds after start from the bridgeTroubleshootingSteering Gear · HyundaiIn the evening the running steering gear pump stopped, and the standby pump started. Started from the bridge (autopilot), the pump motor ran for about 4 seconds and then stopped. No alarms on the…Anonymous · 3 y▲0 rating0 commentsWhy anchors and anchor chains are lost or damagedKnowledgeDeck MachineryAnchors and chains are lost or damaged through a mix of technical wear, operational mistakes and use beyond the design limits of the equipment. This is a general note, not one fault case. When…Anonymous · 4 y▲0 rating0 commentsMAN ME HCU and HPS event logs: compare only with the same engineKnowledgeMain Engine · MAN Energy Solutions ME (electronically controlled)HCU and HPS event logs from the MOP are a useful troubleshooting tool on MAN ES ME engines, but you can only compare events from the same engine. These are my notes on what the events are, how I view…Anonymous · 3 y▲0 rating0 commentsISO 4406 vs ISO 4407: oil cleanliness code vs particle countingKnowledgeMain Engine · MAN Energy Solutions ME / ME-B / ME-CISO 4406 is the cleanliness code MAN refers to for main engine system oil on its electronically controlled 2-stroke engines (ME type); ISO 4407 and ISO 11500 are particle counting methods. This note…Anonymous · 2 y▲0 rating0 commentsEngine room fire: fuel backflow through an open return line (Scot Stuttgart)IncidentAuxiliary Engine · "" · ER fire alarm, thick white smoke in port ERChemical tanker with two engine rooms, alongside in San Juan discharging cargo. The port AE was under LOTO for turbocharger and aftercooler cleaning. The crew removed the aftercooler and the fuel…Anonymous · 2 mo