Alfa Laval SA820: "Sludge in bowl" alarm every day or two after overhaul
Troubleshooting
Purifier
·
Alfa Laval SA820
·
Sludge in bowl
After an overhaul the separator ran normally for several days. Then the "Sludge in bowl" alarm came every one or two days. The separator had tried to calibrate itself and could not close the bowl.
Anonymous · 5 y
▲
0
rating
0
comments
Atlas incinerator will not burn sludge: no start signal to dosing pump
Troubleshooting
Incinerator & Sewage
·
Atlas
The incinerator would not burn sludge. Chamber temperature rose normally and reached the set point for starting the sludge burner. But the PLC gave no output signals: no "dosing pump ready to start",…
Anonymous · 6 y
▲
0
rating
0
comments
Westfalia OSD 18: weak sludge discharge when hydrophore pressure is low
Troubleshooting
Purifier
·
Westfalia OSD 18
Poor sludge discharge: no normal "bang", the bowl only "sneezes" and little comes out. Everything else worked correctly. With the hydrophore at 5.1–5.6 bar the discharge was normal. At 4.3 bar the…
Anonymous · 4 y
▲
0
rating
0
comments
Alfa Laval SA805 lube oil separator: bowl opens by itself after about 10 hours
Troubleshooting
Purifier
·
Alfa Laval SA805
·
Low back pressure
The separator ran for about 10 hours, then the bowl opened by itself. The closing water went to the drain, and nothing held the bowl closed. Alarm: "Low back pressure". The other two separators…
Anonymous · 4 y