Log inJoin
Search

Cases

0 rating0 commentsAlfa Laval plate FWG: high brine temperature (60 °C) and low outputTroubleshootingFresh Water Generator · Alfa Laval (plate type)Low fresh water output and brine temperature up to 60 °C. Cleaning the plates did not help. Vacuum and heating water were normal. Readings, the same before and after cleaning: Reading Value Heating…Anonymous · 10 mo0 rating0 commentsFresh water generator: checklist for low output or high salinityProcedureFresh Water GeneratorThis is my checklist for a fresh water generator (FWG) that makes too little water or gives high salinity in the distillate. It applies to a vacuum evaporator heated by engine jacket water, where an…Anonymous · 4 y0 rating0 commentsDaihatsu 6DK generator: testing overspeed without a test buttonKnowledgeAuxiliary Engine · Anqing Daihatsu 6DK, Nanjing Chuzheng speed switchThe generator engine has a separate speed switch unit (Nanjing Chuzheng). It has no test button. The settings on its label: Setting Value Low speed 300 rpm Rated speed 720 rpm Overspeed 815 rpm…Anonymous · 6 y0 rating0 commentsEngine room fire: fuel backflow through an open return line (Scot Stuttgart)IncidentAuxiliary Engine · "" · ER fire alarm, thick white smoke in port ERChemical tanker with two engine rooms, alongside in San Juan discharging cargo. The port AE was under LOTO for turbocharger and aftercooler cleaning. The crew removed the aftercooler and the fuel…Anonymous · 2 mo