Two-stroke main engine will not start without an auxiliary blower
Knowledge
Main Engine
A two-stroke main engine (M/E) will not start unless at least one auxiliary blower is running; the control software blocks the start, so in practice it works as a start interlock. The M/E will start…
Anonymous · 3 y
▲
0
rating
0
comments
Mitsubishi deck crane will not start after a limit switch stop
Troubleshooting
Deck Machinery
·
Mitsubishi
The crane limit switches were being tested during a class survey. A limit switch tripped and the crane stopped. After that the crane would not start at all. There were no alarms.
Anonymous · 1 y
▲
0
rating
0
comments
Main switchboard low insulation: find the fault by isolating loads
Procedure
Electrical
·
Low insulation
This is how I find the cause of a low insulation alarm or low reading on the main switchboard (MSB): isolate all loads, then reconnect them one at a time while watching the insulation monitor. It…
Anonymous · 4 y
▲
0
rating
0
comments
Oil tanker aux boilers: tests before cargo discharge
Procedure
Boiler
Before cargo discharge on an oil tanker, I test the auxiliary boilers so they keep working through the discharge: boiler water, controls, and the pumps under load. This applies to any boiler maker…
Anonymous · 4 y
▲
0
rating
0
comments
Aux boiler explosion: waxy MGO, then fan restart into a gassy furnace (Manhattan Bridge)
Incident
Boiler
·
""
·
Aux boiler emergency trip (Furnace flame-eye abnormal)
A 13,900 TEU container ship was berthing at Felixstowe in winter. The auxiliary boiler (rotary cup burner) had been on MGO for three days for the ECA. It tripped four times between 17:30 and 19:51.…
Anonymous · 8 y