HFO to MGO changeover: cool slowly and watch viscosity
EL-0160 · Procedure · rating 0 · occurred 06 Jan 2023
Source: /cases/el-0160
Scope#
Changing the main engine and diesel generators from HFO to MGO is safe if fuel temperature falls slowly and viscosity stays between 2 cSt and 20 cSt. This is the general procedure I use; it follows what many marine diesel engine makers recommend, though I can't point to a specific maker or service letter.
It covers only the change from HFO to MGO, for marine diesel engines in general. I have no separate advice for the main engine and the generators, and it is not tied to a fault or alarm.
Safety#
- The fuel temperature and viscosity must change slowly and stay inside limits. Fast changes can harm fuel system parts, such as the fuel pumps.
- Limits I work to:
- Fuel viscosity must stay between
2 cStand20 cSt. - Fuel temperature at the fuel pump inlet must not fall faster than
2 °Cper minute.
- Fuel viscosity must stay between
- Follow the engine operation book for your engine. Its limits come first.
Tools & parts#
- Viscosity controller on the fuel heater (normally in auto, controlling the steam valve).
- Temperature and viscosity readings on the fuel line.
- A tool to check the fuel pump body temperature. My notes say "refractometer"; this is probably a mistake for an IR thermometer or pyrometer, but I am not sure.
Steps#
- Before you start, check how warm the MGO in the service tank is. At that temperature it must give a suitable viscosity at the engine inlet.
- Reduce engine load. A load of
25–40 %is normal, so the fuel temperature falls slowly. In my experience a higher load of up to about75 %is possible, but only if the engine operation book allows it. - Stop the steam tracing. Stop steam to the fuel preheater.
- When the fuel temperature starts to fall, switch the fuel changeover valve to MGO.
- Watch temperature and viscosity during the whole change. Normally the viscosity controller runs the heater steam valve. If the readings need it, switch the controller to manual and run the steam valve by hand. This protects the fuel system parts.
- As a precaution, check the fuel pump body temperature from start to finish.
- Expect a long time. It can take several hours until the system holds only MGO. A higher load, a larger volume of fuel in the circulating circuit, or a different system layout will change this time.
Check after#
- Fuel viscosity stayed between
2 cStand20 cStduring the change. - Temperature at the fuel pump inlet did not fall faster than
2 °Cper minute. - Fuel pump body temperatures were checked through the whole change.
- Only MGO is left in the system.
- I have no recorded outcome from a specific changeover to report.
Comments · 0