0 rating0 commentsEngine room flooding from a corroded sea water pipe at the strainer (Oliver Hazard Perry)IncidentAuxiliary Engine · John Deere diesel generator · AC power fault alarm on fire alarm panel, blackoutSail training tall ship (128 ft), two Caterpillar C12 propulsion engines, two John Deere DGs (99 kW). Moored, one crewmember on board. Shore power breakers kept tripping, so the port DG ran…Anonymous · 7 mo0 rating0 commentsBoiler feed pumps air-lock every few hours and trip on low pressureTroubleshootingBoilerBoiler feed water pumps get air-locked. After venting they run for 2–3 hours (sometimes up to 2 days), then the same again. Both pump motors trip. Low pressure alarms on the boiler panel, mostly at…Anonymous · 1 y0 rating0 commentsIMO fuel supply pump gives only 5 bar on diesel oilTroubleshootingPumps · IMOThe fuel supply pumps (IMO screw pumps) gave only about 5 bar when running on diesel oil. The ship rarely ran on diesel, so the fault went unnoticed for a long time. It took three months to find.Anonymous · 2 y0 rating0 commentsBallast pump coupling stuck: removed without heat using an extractor and jackTroubleshootingPumpsA stuck coupling flange on a tanker ballast pump can be pulled off without heat using a home-made extractor and a hydraulic jack. That is how we freed ours. The ballast pump sits in the pump room of…Anonymous · 2 y0 rating0 commentsHFO transfer pump: start relay chatters, pump will not start in manualTroubleshootingPumpsWhen Start is pressed, relay 4 in the starter crackles and buzzes. The main contactor does not pull in. The main contactor is new. With one output wire of the control circuit disconnected, the pump…Anonymous · 2 y0 rating0 commentsThermal oil fire from a failing pump bearing, water mist did not work (Pride of Hull)IncidentPumps · Allweiler NTT 80-200 · ER fire alarm, zone "Oil treatment pumps"Ro-ro passenger ferry, outbound in the Humber. Thermal oil (Texatherm 32, winter set point 170 °C) carried heat from the economisers and a boiler. Circulation pump #1 was on duty. The fire panel…Anonymous · 4 y0 rating0 commentsFire pump 115 kW: main breaker trips at star-delta changeoverTroubleshootingPumpsTwo fire pumps, 115 kW each. One starts normally. The other runs up on star without problems. At the changeover to delta, the main breaker trips. At the changeover, the current goes off the scale of…Anonymous · 6 y0 rating0 commentsSea water cooling pump: no pressure and low current after overhaulTroubleshootingPumpsThe cooling sea water pump had just been overhauled, and a new motor was fitted: 25.3 kW, 39.5 A, 440 V delta, 1800 rpm. After start the pump gave no pressure. Motor current rose from 17 A to 24 A…Anonymous · 7 y