Search
Cases
Search cases
Clear
⌘K
All
6
Solved
0
Open
0
Troubleshooting
Incident analysis
Procedure
Knowledge
6 cases match
Equipment
All
Main Engine
Auxiliary Engine
Turbocharger
Boiler
Purifier
Compressed Air
Pumps
Fresh Water Generator
OWS & Bilge
Incinerator & Sewage
Refrigeration & HVAC
Steering Gear
Propulsion & Thrusters
Deck Machinery
Ballast System
Electrical
Automation / PLC
Navigation
Fire & Safety
Other
Sort
Best match
Newest first
Highest rated
Most confirmed
Recently updated
Apply
▲
0
rating
0
comments
ISO 4406 vs ISO 4407: oil cleanliness code vs particle counting
Knowledge
Main Engine
·
MAN Energy Solutions ME / ME-B / ME-C
ISO 4406 is the cleanliness code MAN refers to for main engine system oil on its electronically controlled 2-stroke engines (ME type); ISO 4407 and ISO 11500 are particle counting methods. This note…
Anonymous · 2 y
▲
0
rating
0
comments
Bunker fuel quality: ISO 8217 fuel can still cause engine problems
Knowledge
Main Engine
These are my general notes about bunker fuel quality. They do not describe a real fault on a ship. I give no engine maker, no readings and no test results. I wrote them in two parts. Main point…
Anonymous · 2 y
▲
0
rating
0
comments
Tanker fixed gas sampling system: monthly and yearly checks
Knowledge
Fire & Safety
The fixed gas sampling system on an oil tanker needs monthly crew checks (visual inspection, alarm test, zero and span calibration) plus, as good practice, a yearly health check by an authorized…
Anonymous · 4 y
▲
0
rating
0
comments
Two-stroke main engine: jobs to do while stopped in port or at anchor
Knowledge
Main Engine
·
MAN ES ME / MC
This is my checklist of jobs to plan when the two-stroke main engine is stopped in port or at anchor and there is a good chance to do the work. It leaves out inspections that are due by running…
Anonymous · 4 y
▲
0
rating
0
comments
OWS 15 ppm monitor cannot detect a blocked sampling line
Knowledge
OWS & Bilge
·
JOWA; Bilgemon488 15 ppm monitor
A 15 ppm bilge alarm without a low sample flow switch cannot tell when its sampling line is closed or blocked, so the OWS can keep discharging overboard. A poorly placed sampling point can also make…
Anonymous · 3 y
▲
0
rating
0
comments
Shipboard incinerator: how to keep it in good condition
Knowledge
Incinerator & Sewage
Keeping a shipboard incinerator in good condition mostly means clean air inlets and burner parts, a slow shutdown, careful sludge handling and sensible loading. These are the practices I follow,…
Anonymous · 4 y
EngineLog
Home
Cases
Assistant
Library
Log in
Join
Home
Cases
Assistant
Library