0 rating0 commentsBoll & Kirch filter turns back to the dirty chamber at flushingTroubleshootingOther · Boll & Kirch 6.72, BK 2200 controllerAt backflushing: The solenoid worked and the filter turned to the clean chamber. The solenoid switched off, air was cut, and the filter turned back to the dirty chamber. This happened twice in a row.…Anonymous · 5 y0 rating0 commentsYanmar generator: low LO pressure shutdown 5 minutes after startTroubleshootingAuxiliary Engine · YanmarAfter start, LO pressure was normal (4.8 bar), then slowly fell. After 5–6 minutes at most, the engine shut down on low LO pressure. The differential pressure indicator on the automatic LO filter…Anonymous · 4 y0 rating0 commentsGenerator con-rod seizes and holes the block: oil run far past interval (Ocean Navigator)IncidentAuxiliary Engine · Caterpillar 3516B · ER fire alarm, AE2 low LO pressure and oil filter plugged, blackoutAE2 on a coastal cruise ship (Caterpillar 3516B, 1,800 rpm) had run its LO for more than 5,000 h and its filter elements for 3,329 h. Both should be changed at 1,000 h (LO longer only under…Anonymous · 1 y0 rating0 commentsUsing a new bunker before the lab report arrives: precautionsProcedureMain EngineWhen a ship has to change over to a new bunker before the lab report arrives, I treat the fuel as suspect and run with extra precautions on fuel treatment and engines until the result is known. The…Anonymous · 4 y0 rating0 commentsVolvo Penta D16: con-rods through crankcase from swapped big-end caps (Wight Sky)IncidentMain Engine · Volvo Penta D16 MH · ME2 low LO pressure shutdown; ME4 common alarmRo-ro ferry with four Volvo Penta D16 MH high-speed MEs; one or two drive each Voith Schneider unit through fluid couplings. Wight Sky had three catastrophic ME failures in 15 months. The 2017 one…Anonymous · 4 y0 rating0 commentsSchaller Visatron VN215 oil mist detector: error E 012 a week after serviceTroubleshootingMain Engine · Schaller Visatron VN215/93 · E 012The oil mist detector was fully serviced: optics cleaned, filters changed, negative pressure set as per the manual. One week later it showed error E 012.Anonymous · 2 y0 rating0 commentsISO 4406 vs ISO 4407: oil cleanliness code vs particle countingKnowledgeMain Engine · MAN Energy Solutions ME / ME-B / ME-CISO 4406 is the cleanliness code MAN refers to for main engine system oil on its electronically controlled 2-stroke engines (ME type); ISO 4407 and ISO 11500 are particle counting methods. This note…Anonymous · 2 y0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y0 rating0 commentsAlfa Laval SA805 lube oil separator: bowl opens by itself after about 10 hoursTroubleshootingPurifier · Alfa Laval SA805 · Low back pressureThe separator ran for about 10 hours, then the bowl opened by itself. The closing water went to the drain, and nothing held the bowl closed. Alarm: "Low back pressure". The other two separators…Anonymous · 4 y0 rating0 commentsBunker fuel quality: ISO 8217 fuel can still cause engine problemsKnowledgeMain EngineThese are my general notes about bunker fuel quality. They do not describe a real fault on a ship. I give no engine maker, no readings and no test results. I wrote them in two parts. Main point…Anonymous · 2 y0 rating0 commentsTanker fixed gas sampling system: monthly and yearly checksKnowledgeFire & SafetyThe fixed gas sampling system on an oil tanker needs monthly crew checks (visual inspection, alarm test, zero and span calibration) plus, as good practice, a yearly health check by an authorized…Anonymous · 4 y0 rating0 commentsSauer air-cooled service air compressor overheats (105 °C)TroubleshootingCompressed Air · Sauer Compressors, Air Control 1 controllerThe air-cooled service air compressor overheated. The controller showed 105 °C at 5.6 bar.Anonymous · 2 y0 rating0 commentsTwo-stroke main engine: jobs to do while stopped in port or at anchorKnowledgeMain Engine · MAN ES ME / MCThis is my checklist of jobs to plan when the two-stroke main engine is stopped in port or at anchor and there is a good chance to do the work. It leaves out inspections that are due by running…Anonymous · 4 y0 rating0 answersStern tube oil: high copper, cooler or pump wear suspectedTroubleshootingOpenPropulsion & ThrustersOur stern tube lube oil showed high copper (60-80 ppm); the cause is not confirmed, and I suspect wear in the oil cooler or circulating pumps rather than the bearing. Lab analysis of the stern tube…Anonymous · 4 y0 rating0 commentsAalborg thermal oil boiler: no fuel from the nozzle at ignitionTroubleshootingBoiler · Aalborg, LAL burner controlAfter a safety alarm test the boiler stopped and did not start again. The coil of the recirculation (return) solenoid valve had burnt. It had run hot for a long time: it looked melted and its wiring…Anonymous · 1 y0 rating0 commentsMain engine: gas bubbles in the fuel system, fuel pressure jumpingTroubleshootingMain EngineAir (gas) bubbles in the main engine fuel oil system. Small bubbles stayed all the time. Fuel pressure was jumping.Anonymous · 1 y0 rating0 commentsMAN 6S50ME-C: unit loses compression 10 minutes after overhaulTroubleshootingMain Engine · MAN B&W 6S50ME-CUnit 1 of the main engine was overhauled. Tests in port were normal. About 10 minutes after leaving port, the unit started knocking and lost compression. After a restart the unit worked again, but…Anonymous · 4 y0 rating0 commentsOWS 15 ppm monitor cannot detect a blocked sampling lineKnowledgeOWS & Bilge · JOWA; Bilgemon488 15 ppm monitorA 15 ppm bilge alarm without a low sample flow switch cannot tell when its sampling line is closed or blocked, so the OWS can keep discharging overboard. A poorly placed sampling point can also make…Anonymous · 3 y0 rating0 commentsShipboard incinerator: how to keep it in good conditionKnowledgeIncinerator & SewageKeeping a shipboard incinerator in good condition mostly means clean air inlets and burner parts, a slow shutdown, careful sludge handling and sensible loading. These are the practices I follow,…Anonymous · 4 y0 rating0 commentsAux boiler explosion: waxy MGO, then fan restart into a gassy furnace (Manhattan Bridge)IncidentBoiler · "" · Aux boiler emergency trip (Furnace flame-eye abnormal)A 13,900 TEU container ship was berthing at Felixstowe in winter. The auxiliary boiler (rotary cup burner) had been on MGO for three days for the ECA. It tripped four times between 17:30 and 19:51.…Anonymous · 8 y