▲0 rating0 commentsTwo-stroke load diagram: why the same mep is overload at low rpmKnowledgeMain Engine · MAN B&WOn a MAN B&W two-stroke load diagram, the same mep that is fine at high RPM counts as overload at low RPM because the torque limit is set mainly by the thermal load of engine components, with weak…Anonymous · 3 y▲0 rating0 commentsSOx scrubber failure: what to do to stay compliant (MEPC.1/Circ.883)ProcedureOtherWhen the exhaust gas cleaning system (EGCS, SOx scrubber) fails and no longer meets the scrubber guidelines, I follow IMO MEPC.1/Circ.883, which covers EGCS malfunctions. This procedure sets out the…Anonymous · 4 y▲0 rating0 commentsBWTS in muddy ports: filters clog, how to ballast and when to bypassProcedureBallast SystemBallasting in very muddy water clogs and can damage the BWTS filter; this note covers how I ballast in those ports and when a bypass is allowed. In my experience this happens mostly in Chinese ports.…Anonymous · 4 y▲0 rating0 commentsOWS 15 ppm monitor cannot detect a blocked sampling lineKnowledgeOWS & Bilge · JOWA; Bilgemon488 15 ppm monitorA 15 ppm bilge alarm without a low sample flow switch cannot tell when its sampling line is closed or blocked, so the OWS can keep discharging overboard. A poorly placed sampling point can also make…Anonymous · 3 y▲0 rating0 commentsOpen-loop SOx scrubber: common problems with pipes, sensors and pumpsKnowledgeOtherThese are the usual trouble spots on SOx scrubbers, from my experience and from one other engineer. We both talk about open-loop systems. I do not name a ship, engine or scrubber maker here. This is…Anonymous · 4 y