Search

Cases

0 rating0 commentsWestfalia OSD 60-91: bowl does not close, ejection monitoring alarmTroubleshootingPurifier · Westfalia OSD 60-91 · Ejection monitoringTwo main engine LO separators stopped one after the other on the ejection monitoring alarm. On both, the bowl did not close at all. No discharge either, not even a small one. No. 1 stopped 1,000…Anonymous · 2 y0 rating0 commentsWestfalia OSD 18: weak sludge discharge when hydrophore pressure is lowTroubleshootingPurifier · Westfalia OSD 18Poor sludge discharge: no normal "bang", the bowl only "sneezes" and little comes out. Everything else worked correctly. With the hydrophore at 5.1–5.6 bar the discharge was normal. At 4.3 bar the…Anonymous · 4 y0 rating0 commentsAlfa Laval SA805 lube oil separator: bowl opens by itself after about 10 hoursTroubleshootingPurifier · Alfa Laval SA805 · Low back pressureThe separator ran for about 10 hours, then the bowl opened by itself. The closing water went to the drain, and nothing held the bowl closed. Alarm: "Low back pressure". The other two separators…Anonymous · 4 y0 rating0 commentsLNG dual-fuel ship: how the fuel gas supply system worksKnowledgeMain EngineThe fuel gas supply system (FGSS) on an LNG dual-fuel ship controls boil-off gas pressure in the LNG fuel tanks and turns LNG into gas for the engines and boilers; its design is set mainly by the…Anonymous · 3 y0 rating0 commentsAft stern tube bearing wiped by partial propeller immersionKnowledgePropulsion & ThrustersRunning with the propeller not fully immersed puts off-centre thrust on the shaft, which edge-loads the aft stern tube bearing and can wipe its white metal within minutes. My main reference is DNV GL…Anonymous · 4 y