Schaller Visatron VN215 oil mist detector: error E 012 a week after service
Troubleshooting
Main Engine
·
Schaller Visatron VN215/93
·
E 012
The oil mist detector was fully serviced: optics cleaned, filters changed, negative pressure set as per the manual. One week later it showed error E 012.
Anonymous · 2 y
▲
0
rating
0
comments
AC plant with two compressors: valves do not open on one compressor
Troubleshooting
Refrigeration & HVAC
AC plant with two compressors on one large AHU. With one compressor running alone, the refrigerant valves to the AHU cooling coil did not open. The controller gave no open command at all. The problem…
Anonymous · 4 y
▲
0
rating
0
comments
Alfa Laval SA820: "Sludge in bowl" alarm every day or two after overhaul
Troubleshooting
Purifier
·
Alfa Laval SA820
·
Sludge in bowl
After an overhaul the separator ran normally for several days. Then the "Sludge in bowl" alarm came every one or two days. The separator had tried to calibrate itself and could not close the bowl.
Anonymous · 5 y
▲
0
rating
0
comments
MAN 6S50ME-B: high exhaust temperature on all cylinders at part load
Troubleshooting
Main Engine
·
MAN B&W 6S50ME-B
At 82–85 rpm (about 55% load; normal sea speed is 90 rpm), exhaust temperature rose on all six cylinders. Exhaust outlet temperatures were 416–437 °C, mean 427 °C. At sea trial this was about 340 °C.…
Anonymous · 2 y
▲
0
rating
0
comments
MAN B&W ES main engine: precautions for long low-load running
Knowledge
Main Engine
·
MAN B&W ES
MAN Service Letter SL09-511/MTS gives 10% load as the lowest load for continuous running of a MAN B&W ES two-stroke main engine, and running in this range needs precautions. These are the precautions…
Anonymous · 4 y
▲
0
rating
0
comments
MAN ME HCU and HPS event logs: compare only with the same engine
Knowledge
Main Engine
·
MAN Energy Solutions ME (electronically controlled)
HCU and HPS event logs from the MOP are a useful troubleshooting tool on MAN ES ME engines, but you can only compare events from the same engine. These are my notes on what the events are, how I view…
Anonymous · 3 y