Himsen 6H21/32: lowering the main bearing cap far enough to change the bearing
Knowledge
Auxiliary Engine
·
Himsen 6H21/32
When the main bearing cap is lowered with the special tool as the manual says, it goes down only 7–8 cm. That is not enough to change the bearing.
Anonymous · 1 y
▲
0
rating
0
comments
Bunker fuel quality: ISO 8217 fuel can still cause engine problems
Knowledge
Main Engine
These are my general notes about bunker fuel quality. They do not describe a real fault on a ship. I give no engine maker, no readings and no test results. I wrote them in two parts. Main point…
Anonymous · 2 y
▲
0
rating
0
comments
Yanmar generators: look-alike turbochargers are not interchangeable
Knowledge
Turbocharger
·
Yanmar
A ship had three Yanmar diesel generators: two with 1600 kW generators and one with a 1200 kW generator. The diesel engines were the same, and the turbochargers looked the same from outside. But the…
Anonymous · 2 y
▲
0
rating
0
comments
LNG dual-fuel ship: how the fuel gas supply system works
Knowledge
Main Engine
The fuel gas supply system (FGSS) on an LNG dual-fuel ship controls boil-off gas pressure in the LNG fuel tanks and turns LNG into gas for the engines and boilers; its design is set mainly by the…
Anonymous · 3 y
▲
0
rating
0
comments
Doosan emergency generator: testing overspeed without a test button
Knowledge
Auxiliary Engine
·
Doosan AD136TS, KMC ECMS-850EH
·
Overspeed
The set: Doosan AD136TS engine (1800 rpm, 125 kW) with a KMC ECMS-850EH engine control and monitoring system. The wiring diagram in the manual shows a GAC ESD5550 speed control unit with "TEST…
Anonymous · 3 y
▲
0
rating
0
comments
Fuel treatment chemicals: why engine makers prefer good fuel management
Knowledge
Main Engine
The big makers of main and generator engines prefer good fuel management to fuel treatment chemicals; they have not confirmed the claimed benefits of additives. The one exception I make is a…
Anonymous · 4 y
▲
0
rating
0
comments
Daihatsu 6DK generator: testing overspeed without a test button
Knowledge
Auxiliary Engine
·
Anqing Daihatsu 6DK, Nanjing Chuzheng speed switch
The generator engine has a separate speed switch unit (Nanjing Chuzheng). It has no test button. The settings on its label: Setting Value Low speed 300 rpm Rated speed 720 rpm Overspeed 815 rpm…
Anonymous · 6 y
▲
0
rating
0
comments
Emergency generator: all alarms when the rack bracket is released
Knowledge
Auxiliary Engine
After a manual (emergency) start, the fuel rack is held by a locking bracket. If this bracket is released while the engine runs, the engine stops at once and all alarms come up together.
Anonymous · 7 y