▲0 rating0 commentsMAN ME-C: "Low stroke" slowdown, exhaust valve position signal drops outTroubleshootingMain Engine · MAN B&W ME-C · Low strokeMain engine slowdown with "Low stroke" alarm on one cylinder. On the MOP, the exhaust valve position signal from the inductive sensor dropped out about every 3 seconds. Each time, fuel injection to…Anonymous · 8 mo▲0 rating0 commentsDiesel oil bunkering: tank overflow through a taped vent, engine room fire (Stride)IncidentBoiler · MAN B&W 7S70MC Mk6 · Diesel oil seen dripping from upper ER; no tank high-level alarm recordedGeneral cargo ship alongside at LaPorte, Texas, taking 80 mt of LSMGO into the port and starboard double-bottom DO tanks. The C/E and 3/E ran the bunkering from the ECR, with both fill valves open.…Anonymous · 1 y▲0 rating0 commentsMAN 6S50ME-B: high exhaust temperature on all cylinders at part loadTroubleshootingMain Engine · MAN B&W 6S50ME-BAt 82–85 rpm (about 55% load; normal sea speed is 90 rpm), exhaust temperature rose on all six cylinders. Exhaust outlet temperatures were 416–437 °C, mean 427 °C. At sea trial this was about 340 °C.…Anonymous · 2 y▲0 rating0 commentsCPP hub oil loss from a cracked blade foot, not a blade seal (Maunalei)IncidentPropulsion & Thrusters · MAN Energy Solutions Mark 5 CPP; MAN B&W 7L70MC-C · Engineering alarm, CPP hub head tank found emptyContainership, MAN B&W 7L70MC-C two-stroke ME directly coupled to a 5-blade MAN Mark 5 CPP. On passage to Anchorage an alarm came up: CPP hub head tank empty. The crew reduced pitch and refilled the…Anonymous · 2 y▲0 rating0 commentsFatal engine room fire after opening a pressurised fuel filter (Moritz Schulte)IncidentAuxiliary Engine · MAN B&W L23/30H · ER fire alarmLPG carrier discharging alongside in Antwerp. AE2 and AE3 were running and AE1 was on standby. After the morning toolbox talk the newly promoted 3/E asked the 2/E if he could clean the AE1 fuel…Anonymous · 3 y▲0 rating0 commentsMAN MC-C: no combustion in one unit, clogged ball valve at fuel pump inletTroubleshootingMain Engine · MAN B&W MC-C · Slowdown: exhaust gas temperature deviation, cylinder No.6Cylinder No.6 on our MAN MC-C stopped firing because the ball valve on the fuel oil inlet to its fuel pump was clogged. It took a long list of new parts before we found it. We reduced main engine…Anonymous · 4 y▲0 rating0 commentsMAN 6S50ME-C: unit loses compression 10 minutes after overhaulTroubleshootingMain Engine · MAN B&W 6S50ME-CUnit 1 of the main engine was overhauled. Tests in port were normal. About 10 minutes after leaving port, the unit started knocking and lost compression. After a restart the unit worked again, but…Anonymous · 4 y▲0 rating0 commentsAlpha Lubricator: "Feedback failure" slowdown comes and goesTroubleshootingMain Engine · MAN B&W Alpha Lubricator · Feedback failureMain engine slowdown from the Alpha Lubricator system, alarm "Feedback failure". The alarm came for 5 to 60 seconds and then cleared by itself. In the menu it showed as Alarm 3. By the manual, Alarm…Anonymous · 4 y▲0 rating0 commentsMAN B&W 7S70MC: fuel pump roller will not lower back after repair in portTroubleshootingMain Engine · MAN B&W 7S70MCAt sea, one fuel pump was cut out with the pneumatic fuel pump lifting device (roller lifted off the cam). The pump was repaired in port. The lifting device would not lower the roller back.Anonymous · 4 y