▲0 rating0 commentsBallast valve remote control: half the valves stop responding, no alarmTroubleshootingBallast System · Utsuki valve remote control, Yokogawa FA-M3 PLCAbout half of the hydraulic ballast valves stopped responding, all at the same time. No reaction from the ballast console or from the local control panel. No alarms. The valves could still be moved…Anonymous · 6 y▲0 rating0 commentsMAN MC-C: no combustion in one unit, clogged ball valve at fuel pump inletTroubleshootingMain Engine · MAN B&W MC-C · Slowdown: exhaust gas temperature deviation, cylinder No.6Cylinder No.6 on our MAN MC-C stopped firing because the ball valve on the fuel oil inlet to its fuel pump was clogged. It took a long list of new parts before we found it. We reduced main engine…Anonymous · 4 y▲0 rating0 commentsBWTS valve with Siemens SIPART PS2 positioner: alarm A29, valve limit switchTroubleshootingBallast System · Siemens SIPART PS2 6DR5020-0NG30-0AB0 · A29The ballast water treatment system gave alarm A29: limit switch fault on a valve. The limit switch is inside the valve positioner, wired to terminals 41–42.Anonymous · 6 y▲0 rating0 commentsWeishaupt Monarch burner sprays fuel as soon as the fan startsTroubleshootingBoiler · Weishaupt MonarchFuel sprayed from the nozzle as soon as the burner fan motor started, during pre-purge. It should spray only after purge, when the air damper closes, together with ignition. The burner started and…Anonymous · 6 y▲0 rating0 commentsAalborg thermal oil boiler: no fuel from the nozzle at ignitionTroubleshootingBoiler · Aalborg, LAL burner controlAfter a safety alarm test the boiler stopped and did not start again. The coil of the recirculation (return) solenoid valve had burnt. It had run hot for a long time: it looked melted and its wiring…Anonymous · 1 y▲0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y▲0 rating0 commentsFatal engine room fire after opening a pressurised fuel filter (Moritz Schulte)IncidentAuxiliary Engine · MAN B&W L23/30H · ER fire alarmLPG carrier discharging alongside in Antwerp. AE2 and AE3 were running and AE1 was on standby. After the morning toolbox talk the newly promoted 3/E asked the 2/E if he could clean the AE1 fuel…Anonymous · 3 y