Teamtec OG400 incinerator: "Communication failure PLC - display" after battery change
Troubleshooting
Incinerator & Sewage
·
Teamtec OG400
·
Communication failure PLC - display
The PLC battery was replaced with the incinerator switched off from the mains. After switching on: "Communication failure PLC - display". All PLC data and settings were lost.
Anonymous · 5 y
▲
0
rating
0
comments
Ballast valve remote control: half the valves stop responding, no alarm
Troubleshooting
Ballast System
·
Utsuki valve remote control, Yokogawa FA-M3 PLC
About half of the hydraulic ballast valves stopped responding, all at the same time. No reaction from the ballast console or from the local control panel. No alarms. The valves could still be moved…
Anonymous · 6 y
▲
0
rating
0
comments
Kangrim boiler: "Flame failure" alarm while stopped, will not reset
Troubleshooting
Boiler
·
Kangrim
·
Flame failure
FLAME FAILURE alarm came up while the boiler was stopped (not firing). The alarm could not be reset. A restart did not help.
Anonymous · 2 y
▲
0
rating
0
comments
Mooring winch with frequency converter: speed does not change with the joystick
Troubleshooting
Deck Machinery
An inverter-driven mooring winch stopped regulating speed from the joystick.
Anonymous · 1 y
▲
0
rating
0
comments
Atlas incinerator will not burn sludge: no start signal to dosing pump
Troubleshooting
Incinerator & Sewage
·
Atlas
The incinerator would not burn sludge. Chamber temperature rose normally and reached the set point for starting the sludge burner. But the PLC gave no output signals: no "dosing pump ready to start",…
Anonymous · 6 y
▲
0
rating
0
comments
NMF deck crane: no POWER REQUEST after flooding, CPU blinks RUN/STOP
Troubleshooting
Deck Machinery
·
NMF crane, Moeller XC-CPU201
The cranes were badly flooded: slip rings and control panels. Slip rings and panels were cleaned and dried. The cranes had been without power for 2 days. Cranes 1 and 3 started. On crane 2 the POWER…
Anonymous · 3 y
▲
0
rating
0
comments
Siemens LOGO! fuel changeover: program loaded but does not run
Troubleshooting
Automation / PLC
·
Siemens LOGO! 230RC with DM8 230R and AM2 expansion modules
·
Control fail
The automatic HFO/MDO changeover (valves and fuel heating) is controlled by a Siemens LOGO! 230RC with expansion modules. A "Control fail" alarm came up on the fuel page of the control PC. Expansion…
Anonymous · 3 y
▲
0
rating
0
comments
Terasaki PMS: generator will not parallel in auto, "ACB non close"
Troubleshooting
Electrical
·
Terasaki PMS
·
ACB non close
When a generator was put in parallel in automatic mode, the alarm "ACB non close" came up. The breaker did not close and the engine stayed running with no load. Frequency and voltage were the same as…
Anonymous · 4 y