Emergency generator: all alarms when the rack bracket is released
Knowledge
Auxiliary Engine
After a manual (emergency) start, the fuel rack is held by a locking bracket. If this bracket is released while the engine runs, the engine stops at once and all alarms come up together.
Anonymous · 7 y
▲
0
rating
0
comments
Daihatsu 6DK generator: testing overspeed without a test button
Knowledge
Auxiliary Engine
·
Anqing Daihatsu 6DK, Nanjing Chuzheng speed switch
The generator engine has a separate speed switch unit (Nanjing Chuzheng). It has no test button. The settings on its label: Setting Value Low speed 300 rpm Rated speed 720 rpm Overspeed 815 rpm…
Anonymous · 6 y
▲
0
rating
0
comments
Doosan emergency generator: testing overspeed without a test button
Knowledge
Auxiliary Engine
·
Doosan AD136TS, KMC ECMS-850EH
·
Overspeed
The set: Doosan AD136TS engine (1800 rpm, 125 kW) with a KMC ECMS-850EH engine control and monitoring system. The wiring diagram in the manual shows a GAC ESD5550 speed control unit with "TEST…
Anonymous · 3 y
▲
0
rating
0
comments
Yanmar generators: look-alike turbochargers are not interchangeable
Knowledge
Turbocharger
·
Yanmar
A ship had three Yanmar diesel generators: two with 1600 kW generators and one with a 1200 kW generator. The diesel engines were the same, and the turbochargers looked the same from outside. But the…
Anonymous · 2 y
▲
0
rating
0
comments
LNG dual-fuel ship: how the fuel gas supply system works
Knowledge
Main Engine
The fuel gas supply system (FGSS) on an LNG dual-fuel ship controls boil-off gas pressure in the LNG fuel tanks and turns LNG into gas for the engines and boilers; its design is set mainly by the…
Anonymous · 3 y
▲
0
rating
0
comments
Condition based maintenance on tankers and gas carriers: examples
Knowledge
Main Engine
·
MAN ES ME / MC
Condition based maintenance (CBM) on tankers and gas carriers means working on equipment when its condition calls for it; these are the practical examples I use for the main engine, pumps and lube…
Anonymous · 3 y
▲
0
rating
0
comments
Two-stroke main engine: jobs to do while stopped in port or at anchor
Knowledge
Main Engine
·
MAN ES ME / MC
This is my checklist of jobs to plan when the two-stroke main engine is stopped in port or at anchor and there is a good chance to do the work. It leaves out inspections that are due by running…
Anonymous · 4 y
▲
0
rating
0
comments
Fuel treatment chemicals: why engine makers prefer good fuel management
Knowledge
Main Engine
The big makers of main and generator engines prefer good fuel management to fuel treatment chemicals; they have not confirmed the claimed benefits of additives. The one exception I make is a…
Anonymous · 4 y