▲0 rating0 commentsHyundai lift works only in Manual or Inspection mode, not in Auto, no alarmTroubleshootingOther · Hyundai ElevatorIn heavy pitching, the ship slammed into a wave with strong vibration. The lift stopped at that moment. The car was brought down in Manual mode and the breaker was switched off. After switching on…Anonymous · 6 y▲0 rating0 commentsTerasaki PMS: generator will not parallel in auto, "ACB non close"TroubleshootingElectrical · Terasaki PMS · ACB non closeWhen a generator was put in parallel in automatic mode, the alarm "ACB non close" came up. The breaker did not close and the engine stayed running with no load. Frequency and voltage were the same as…Anonymous · 4 y▲0 rating0 commentsHFO transfer pump: start relay chatters, pump will not start in manualTroubleshootingPumpsWhen Start is pressed, relay 4 in the starter crackles and buzzes. The main contactor does not pull in. The main contactor is new. With one output wire of the control circuit disconnected, the pump…Anonymous · 2 y▲0 rating0 commentsHyundai steering gear: pump stops 4 seconds after start from the bridgeTroubleshootingSteering Gear · HyundaiIn the evening the running steering gear pump stopped, and the standby pump started. Started from the bridge (autopilot), the pump motor ran for about 4 seconds and then stopped. No alarms on the…Anonymous · 3 y▲0 rating0 commentsMAN 6S50ME-B: high exhaust temperature on all cylinders at part loadTroubleshootingMain Engine · MAN B&W 6S50ME-BAt 82–85 rpm (about 55% load; normal sea speed is 90 rpm), exhaust temperature rose on all six cylinders. Exhaust outlet temperatures were 416–437 °C, mean 427 °C. At sea trial this was about 340 °C.…Anonymous · 2 y▲0 rating0 commentsSEA-Mate B500 blender stops after blending, blend not dischargedTroubleshootingMain Engine · Marine Fluid Technology SEA-Mate Blender B500In auto mode the unit mixes the oils, then stops and stays stopped. It should open the valve and pump the blend on, but it does not. No alarm.Anonymous · 3 y▲0 rating0 commentsEmergency generator breaker closes and opens again at once, no tripTroubleshootingElectrical · Schneider Masterpact NT06 H2, Micrologic 5.0 AThe emergency generator breaker would not stay closed on the emergency switchboard bus, in both auto and manual mode. On "close" the breaker clicked and closed. The green "closed" indication was on…Anonymous · 4 y▲0 rating0 commentsSiemens LOGO! fuel changeover: program loaded but does not runTroubleshootingAutomation / PLC · Siemens LOGO! 230RC with DM8 230R and AM2 expansion modules · Control failThe automatic HFO/MDO changeover (valves and fuel heating) is controlled by a Siemens LOGO! 230RC with expansion modules. A "Control fail" alarm came up on the fuel page of the control PC. Expansion…Anonymous · 3 y▲0 rating0 commentsAalborg boilers: local panels go offline, fan trips at ignitionTroubleshootingBoiler · AalborgTwo boilers, one ECR PC. First the boiler 1 local panel went offline now and then; a reset helped for a day. Then the boiler 2 local panel went offline, flashing online / offline, and did not reset.…Anonymous · 6 y