▲0 rating0 commentsHyundai lift works only in Manual or Inspection mode, not in Auto, no alarmTroubleshootingOther · Hyundai ElevatorIn heavy pitching, the ship slammed into a wave with strong vibration. The lift stopped at that moment. The car was brought down in Manual mode and the breaker was switched off. After switching on…Anonymous · 6 y▲0 rating0 commentsTerasaki PMS: generator will not parallel in auto, "ACB non close"TroubleshootingElectrical · Terasaki PMS · ACB non closeWhen a generator was put in parallel in automatic mode, the alarm "ACB non close" came up. The breaker did not close and the engine stayed running with no load. Frequency and voltage were the same as…Anonymous · 4 y▲0 rating0 commentsHFO transfer pump: start relay chatters, pump will not start in manualTroubleshootingPumpsWhen Start is pressed, relay 4 in the starter crackles and buzzes. The main contactor does not pull in. The main contactor is new. With one output wire of the control circuit disconnected, the pump…Anonymous · 2 y▲0 rating0 commentsHyundai steering gear: pump stops 4 seconds after start from the bridgeTroubleshootingSteering Gear · HyundaiIn the evening the running steering gear pump stopped, and the standby pump started. Started from the bridge (autopilot), the pump motor ran for about 4 seconds and then stopped. No alarms on the…Anonymous · 3 y▲0 rating0 commentsMAN 6S50ME-B: high exhaust temperature on all cylinders at part loadTroubleshootingMain Engine · MAN B&W 6S50ME-BAt 82–85 rpm (about 55% load; normal sea speed is 90 rpm), exhaust temperature rose on all six cylinders. Exhaust outlet temperatures were 416–437 °C, mean 427 °C. At sea trial this was about 340 °C.…Anonymous · 2 y▲0 rating0 commentsDoppler speed log: water track vs bottom trackKnowledgeNavigationWater track and bottom track on a Doppler speed log use the same Doppler principle; the only difference is the surface that reflects the signal. This note covers how the log works in each mode.…Anonymous · 1 y▲0 rating0 commentsTwo-stroke main engine will not start without an auxiliary blowerKnowledgeMain EngineA two-stroke main engine (M/E) will not start unless at least one auxiliary blower is running; the control software blocks the start, so in practice it works as a start interlock. The M/E will start…Anonymous · 3 y▲0 rating0 commentsSEA-Mate B500 blender stops after blending, blend not dischargedTroubleshootingMain Engine · Marine Fluid Technology SEA-Mate Blender B500In auto mode the unit mixes the oils, then stops and stays stopped. It should open the valve and pump the blend on, but it does not. No alarm.Anonymous · 3 y▲0 rating0 commentsMAN B&W main engine in heavy weather: torque vs rpm governor modeKnowledgeMain Engine · MAN B&W ME-B / ME-C, MCTo protect the main engine liners and piston rings in heavy weather, I reduce RPM and choose the governor mode with care: on ME-B and ME-C engines that means weighing Torque mode against RPM mode.…Anonymous · 3 y▲0 rating0 commentsEmergency generator breaker closes and opens again at once, no tripTroubleshootingElectrical · Schneider Masterpact NT06 H2, Micrologic 5.0 AThe emergency generator breaker would not stay closed on the emergency switchboard bus, in both auto and manual mode. On "close" the breaker clicked and closed. The green "closed" indication was on…Anonymous · 4 y▲0 rating0 commentsSiemens LOGO! fuel changeover: program loaded but does not runTroubleshootingAutomation / PLC · Siemens LOGO! 230RC with DM8 230R and AM2 expansion modules · Control failThe automatic HFO/MDO changeover (valves and fuel heating) is controlled by a Siemens LOGO! 230RC with expansion modules. A "Control fail" alarm came up on the fuel page of the control PC. Expansion…Anonymous · 3 y▲0 rating0 commentsAalborg boilers: local panels go offline, fan trips at ignitionTroubleshootingBoiler · AalborgTwo boilers, one ECR PC. First the boiler 1 local panel went offline now and then; a reset helped for a day. Then the boiler 2 local panel went offline, flashing online / offline, and did not reset.…Anonymous · 6 y▲0 rating0 commentsLNG dual-fuel ship: how the fuel gas supply system worksKnowledgeMain EngineThe fuel gas supply system (FGSS) on an LNG dual-fuel ship controls boil-off gas pressure in the LNG fuel tanks and turns LNG into gas for the engines and boilers; its design is set mainly by the…Anonymous · 3 y▲0 rating0 commentsDual-fuel VLCC: why deck LNG tanks have a water spray systemKnowledgeFire & SafetyThe water spray system around deck LNG fuel tanks has two jobs: it cools the tank and nearby structure in a fire, and it protects carbon steel deck and structure from brittle fracture if LNG leaks or…Anonymous · 4 y▲0 rating0 commentsMAN B&W ES main engine: precautions for long low-load runningKnowledgeMain Engine · MAN B&W ESMAN Service Letter SL09-511/MTS gives 10% load as the lowest load for continuous running of a MAN B&W ES two-stroke main engine, and running in this range needs precautions. These are the precautions…Anonymous · 4 y▲0 rating0 commentsMAN ME: exporting MOP event logs for remote troubleshootingProcedureMain Engine · MAN ES ME (electronically controlled), example engine 6S60ME-CThis is how I export the Event Log and the HCU, HPS and Cylinder Events from the MOP of a MAN ES (formerly MAN Diesel & Turbo) ME engine, to send to a remote troubleshooter. There are two parts:…Anonymous · 4 y▲0 rating0 commentsPods stuck at 90° after overspeed trip and a latched water-leak stop (Spirit of Discovery)IncidentPropulsion & Thrusters · Siemens SISHIp eSiPOD (SiPOD-M10) · Pod water leakage stop (WLS) sequence alarm, then propeller overspeedCruise ship with two Siemens eSiPOD pods (6,500 kW each, no rudder), crossing the Bay of Biscay in force 8–9 wind and 8–9 m waves. At 12:30 the port pod gave a WLS sequence alarm. Very soon after, it…Anonymous · 8 mo