Search

Cases

0 rating0 commentsAutronica: loop fault on Ex detector stays after barrier replacementTroubleshootingFire & Safety · Autronica, BZB 500 interface unit · LOOP FAULTS: LOOP 01 / POINT FAULTS: 10106 SD(EXI)Open-circuit fault on the paint store detector line. The panel showed "LOOP FAULTS 1 LOOP 01" and "POINT FAULTS 1 10106 SD(EXI)". The system did not see the detector.Anonymous · 1 y0 rating0 commentsAlfa Laval PA605 will not start after emergency stop is releasedTroubleshootingPurifier · Alfa Laval PA605 · Emergency button pressThe emergency stop button was pressed. After the button was released, the pump and the separator would not start. The alarm "Emergency button press" stayed on.Anonymous · 2 y0 rating0 commentsMain air compressor will not start, contactor does not pull inTroubleshootingCompressed AirOne main air compressor was opened up for overhaul. Then the other one stopped starting, both in auto and in manual. Pressing Start did nothing.Anonymous · 7 y0 rating0 commentsRolls-Royce steering gear: "Hydraulic lock" alarm at every small rudder movementTroubleshootingSteering Gear · Rolls-Royce · Hydraulic lock"Hydraulic lock" alarm on the steering gear. It started after a service in dry dock. At first it came now and then. Sometimes it cleared by itself, sometimes tightening the contacts helped. Later it…Anonymous · 2 y0 rating0 commentsBallast valve remote control: half the valves stop responding, no alarmTroubleshootingBallast System · Utsuki valve remote control, Yokogawa FA-M3 PLCAbout half of the hydraulic ballast valves stopped responding, all at the same time. No reaction from the ballast console or from the local control panel. No alarms. The valves could still be moved…Anonymous · 6 y0 rating0 commentsHFO transfer pump: start relay chatters, pump will not start in manualTroubleshootingPumpsWhen Start is pressed, relay 4 in the starter crackles and buzzes. The main contactor does not pull in. The main contactor is new. With one output wire of the control circuit disconnected, the pump…Anonymous · 2 y0 rating0 commentsConsilium CS4000: false fire alarm in cargo hold keeps coming backTroubleshootingFire & Safety · Consilium CS4000 · FIRE ALARM — FIRE ZONE 31 IS-DET 43Fire alarm from a cargo hold zone, but there was no fire. The Fault LED was also lit. After a reset the alarm came back the next morning and then would not reset. A full system restart did not help.…Anonymous · 6 mo0 rating0 commentsMacGregor crane: slewing stops with "60 Joystick level error"TroubleshootingDeck Machinery · MacGregor crane, MPC control cards · 60 Joystick level error (normal is 1,5 to 10,5V)The slewing card showed error 60 "Joystick level error (normal is 1,5 to 10,5V)". The crane stopped because of this error.Anonymous · 6 y0 rating0 commentsSiemens LOGO! fuel changeover: program loaded but does not runTroubleshootingAutomation / PLC · Siemens LOGO! 230RC with DM8 230R and AM2 expansion modules · Control failThe automatic HFO/MDO changeover (valves and fuel heating) is controlled by a Siemens LOGO! 230RC with expansion modules. A "Control fail" alarm came up on the fuel page of the control PC. Expansion…Anonymous · 3 y