Search

Cases

0 rating0 commentsSchaller Visatron VN215 oil mist detector: error E 012 a week after serviceTroubleshootingMain Engine · Schaller Visatron VN215/93 · E 012The oil mist detector was fully serviced: optics cleaned, filters changed, negative pressure set as per the manual. One week later it showed error E 012.Anonymous · 2 y0 rating0 commentsAlfa Laval S956: "Bowl speed low" alarm during separationTroubleshootingPurifier · Alfa Laval S956 · Bowl speed low"Bowl speed low" alarm about twice a day. The alarm came during separation, not during discharge. Often it came about 10 hours into the cycle. Between alarms the separator started, reached speed and…Anonymous · 5 y0 rating0 commentsDEIF PPM-3: busbar voltage read too low, generator will not auto-synchroniseTroubleshootingAutomation / PLC · DEIF PPM-3The DEIF PPM-3 controller of one generator measured the busbar voltage lower than it really was. The PMS saw a voltage fault. Auto synchronising was not possible, only manual. When the measured…Anonymous · 2 y0 rating0 commentsSAM Electronics ME HT cooling: temperature swings 8 °C in autoTroubleshootingMain Engine · SAM ElectronicsThe ME HT cooling water temperature controller (HT cooler valve) could not hold the set point in auto. The temperature went up and down by about 8 °C. Because of this, the system was run in manual…Anonymous · 1 y0 rating0 commentsCarel ir33 refrigeration controller: alarm E05 when setpoint is below -18 °CTroubleshootingRefrigeration & HVAC · Carel ir33 · E05With the setpoint at -18 °C everything works. With the setpoint at -18.5 °C or lower, alarm E05 comes. The plant still works and reaches -18.5, -19, -20 °C as set, but the alarm stays.Anonymous · 6 y0 rating0 commentsAC plant with two compressors: valves do not open on one compressorTroubleshootingRefrigeration & HVACAC plant with two compressors on one large AHU. With one compressor running alone, the refrigerant valves to the AHU cooling coil did not open. The controller gave no open command at all. The problem…Anonymous · 4 y0 rating0 commentsAlfa Laval SA820: "Sludge in bowl" alarm every day or two after overhaulTroubleshootingPurifier · Alfa Laval SA820 · Sludge in bowlAfter an overhaul the separator ran normally for several days. Then the "Sludge in bowl" alarm came every one or two days. The separator had tried to calibrate itself and could not close the bowl.Anonymous · 5 y0 rating0 commentsMAN 6S50ME-B: high exhaust temperature on all cylinders at part loadTroubleshootingMain Engine · MAN B&W 6S50ME-BAt 82–85 rpm (about 55% load; normal sea speed is 90 rpm), exhaust temperature rose on all six cylinders. Exhaust outlet temperatures were 416–437 °C, mean 427 °C. At sea trial this was about 340 °C.…Anonymous · 2 y