1 rating0 commentsConsilium CS4000: "IOM70 Synchronisation signal" faultTroubleshootingFire & Safety · Consilium CS4000 · CENTRAL 1 IOM70 51 SYNCHRONISATION SIGNALFault alarm on the water mist main panel: "(212) CENTRAL 1 IOM70 51 SYNCHRONISATION SIGNAL", with "PUMP CONTROL BOX - UNIT FAULT INPUTS". On the I/O M70 module: PS LED flashing yellow, COM LED green.…Anonymous · 6 mo0 rating0 commentsConsilium CS4000: false fire alarm in cargo hold keeps coming backTroubleshootingFire & Safety · Consilium CS4000 · FIRE ALARM — FIRE ZONE 31 IS-DET 43Fire alarm from a cargo hold zone, but there was no fire. The Fault LED was also lit. After a reset the alarm came back the next morning and then would not reset. A full system restart did not help.…Anonymous · 6 mo0 rating0 commentsAutronica: loop fault on Ex detector stays after barrier replacementTroubleshootingFire & Safety · Autronica, BZB 500 interface unit · LOOP FAULTS: LOOP 01 / POINT FAULTS: 10106 SD(EXI)Open-circuit fault on the paint store detector line. The panel showed "LOOP FAULTS 1 LOOP 01" and "POINT FAULTS 1 10106 SD(EXI)". The system did not see the detector.Anonymous · 1 y0 rating0 commentsConsilium CS4000: new manual call point gives "No answer"TroubleshootingFire & Safety · Consilium CS4000 · No answerAn old manual call point (P/N 11305) was replaced with the new type MCP-A, P/N 5200030-01A. The system did not find the new unit: alarm "No answer" for its address, although the address was set…Anonymous · 1 y0 rating0 commentsEltek fire panel: "Fault in addressable loop", but all detectors test OKTroubleshootingFire & Safety · Eltek · FAULT IN ADDRESSABLE LOOP: 01The panel showed FAULT CONDITION: "FAULT IN ADDRESSABLE LOOP: 01". The FAULT lamp was on. The loop worked: the detector test on this loop passed. The manual has no description of this fault. The…Anonymous · 3 y0 rating0 commentsFire detection: "Cable break positive" fault, but voltage everywhereTroubleshootingFire & Safety · LOOP ANALOGUE 2 CABLE BREAK POSITIVE, FAULT(141)Fire alarm panel fault: "LOOP ANALOGUE 2 CABLE BREAK POSITIVE, FAULT(141)", engine room area. The panel showed the break between SCI (short circuit isolator) address 28 and SCI address 39. There are…Anonymous · 4 y0 rating0 commentsConsilium fire detection: five "Sensor fail" alarms from one zoneTroubleshootingFire & Safety · Consilium · Sensor fail, Communication errorFive "Sensor fail" alarms with "Communication error" came up suddenly, all from one zone (pump room). The failed points were on two loops: 3 smoke detectors on loop 2 and 2 manual call points on loop…Anonymous · 6 y0 rating0 commentsFire detection: fault on loop point 2.6, but all loop detectors test OKTroubleshootingFire & SafetyThe fire detection panel showed a fault on loop 2, point 2.6. The ship was in a storm.Anonymous · 6 y0 rating0 commentsNorimos 1000: "Signal syst. power F." alarm and all ventilation stopsTroubleshootingElectrical · Noris Norimos 1000 · SIGNAL SYST.POWER F.The alarm panel showed "SIGNAL SYST.POWER F." (signal system power failure). Right after it, all ventilation stopped. The ship was rolling.Anonymous · 7 y