Search

Cases

0 rating0 commentsAC plant with two compressors: valves do not open on one compressorTroubleshootingRefrigeration & HVACAC plant with two compressors on one large AHU. With one compressor running alone, the refrigerant valves to the AHU cooling coil did not open. The controller gave no open command at all. The problem…Anonymous · 4 y0 rating0 commentsSauer air-cooled service air compressor overheats (105 °C)TroubleshootingCompressed Air · Sauer Compressors, Air Control 1 controllerThe air-cooled service air compressor overheated. The controller showed 105 °C at 5.6 bar.Anonymous · 2 y0 rating0 commentsTMC Tamrotor screw compressor: "R:3137 RUN INHIBIT", "check pressure in pipe"TroubleshootingCompressed Air · TMC Tamrotor EMH 21-44 · R:3137 RUN INHIBITThe display showed 6.0 bar and "R:3137 RUN INHIBIT". The manual has only two alarms marked R. For them it says: "check pressure in pipe".Anonymous · 1 y0 rating0 commentsMain air compressor will not start, contactor does not pull inTroubleshootingCompressed AirOne main air compressor was opened up for overhaul. Then the other one stopped starting, both in auto and in manual. Pressing Start did nothing.Anonymous · 7 y0 rating0 commentsHi Air Korea AC: compressor will not start, "FRESH ARM 1CRUN"TroubleshootingRefrigeration & HVAC · Hi Air Korea · FRESH ARM 1CRUNThe AC compressor did not start. No alarms were showing. When starting the compressor, only the controller on the AC control panel showed a new alarm: FRESH ARM 1CRUN. The manuals do not explain this…Anonymous · 4 mo0 rating0 commentsSauer air compressor keeps tripping, nothing found by handTroubleshootingCompressed Air · SauerThe air compressor tripped again and again for about 1.5 years.Anonymous · 2 y0 rating0 commentsAC compressor loses oil pressure at start after overhaul with new partsTroubleshootingRefrigeration & HVAC · Low oil pressureThe air-conditioning compressors were overhauled with a new spare parts kit. After the overhaul, oil pressure dropped at every start.Anonymous · 1 y0 rating0 commentsProvision plant compressor does not stop at pump-down, overcurrent tripTroubleshootingRefrigeration & HVACThe suction line has two low pressure switches: one stops the compressor, the other opens the unloader valve. When all cold room solenoid valves closed and suction pressure fell, the stop switch did…Anonymous · 7 y0 rating0 commentsBock compressor (AC plant): oil solenoid valve coils overheat and meltTroubleshootingRefrigeration & HVAC · BockAC plant with a Bock compressor. The coil of the oil solenoid valve (220 V, 60 Hz, 10 W) burnt. A new coil heated up very fast and melted. The next coils melted too. Before this, everything had…Anonymous · 1 y