▲1 rating0 commentsHyundai HV switchboard: generator VCB tripped, no reset buttonTroubleshootingElectrical · Hyundai HIMAP-BCThe generator engine shut down on lube oil. HIMAP showed reverse power, and the generator VCB (6600 V) tripped. The breaker could not be reset at the breaker. There is no reset button and no handle…Anonymous · 7 mo▲0 rating0 commentsSwitchboard earth lamps do not light, only one of three on lamp testTroubleshootingElectricalThe insulation resistance monitor (IRM) worked normally. The earth lamps did not light. With the test button pressed, only one of the three lamps lit.Anonymous · 3 mo▲0 rating0 comments220 V insulation alarm every morning, gone before you reach the switchboardTroubleshootingElectrical · Low insulation 220 VLow insulation alarm on the 220 V system early every morning, at breakfast time. By the time the engineer reached the switchboard, the reading was normal again. It started when a new cook joined the…Anonymous · 2 y▲0 rating0 commentsEmergency generator trips on blackout test, then will not close on the busTroubleshootingElectrical · Schneider Electric ComPacT NSX630Blackout test from the main switchboard: the supply to the emergency switchboard was switched off. The emergency generator started, closed onto the bus and took the load. After 5–10 minutes it…Anonymous · 6 mo▲0 rating0 commentsNorimos 1000: "Signal syst. power F." alarm and all ventilation stopsTroubleshootingElectrical · Noris Norimos 1000 · SIGNAL SYST.POWER F.The alarm panel showed "SIGNAL SYST.POWER F." (signal system power failure). Right after it, all ventilation stopped. The ship was rolling.Anonymous · 7 y▲0 rating0 commentsConsilium CS4000: new manual call point gives "No answer"TroubleshootingFire & Safety · Consilium CS4000 · No answerAn old manual call point (P/N 11305) was replaced with the new type MCP-A, P/N 5200030-01A. The system did not find the new unit: alarm "No answer" for its address, although the address was set…Anonymous · 1 y▲0 rating0 commentsThruster start dips the ship's voltage, breaker trips, lights flickerTroubleshootingPropulsion & ThrustersEach time the thruster was started, the ship's voltage dipped. Sometimes the breaker tripped. Other times the lights on board only flickered. Even the radar switched off.Anonymous · 6 y▲0 rating0 commentsHyundai generator: no voltage at start after a 440 V insulation alarmTroubleshootingElectrical · Hyundai HFC7The 440 V insulation reading started to jump between 0 and infinity. Three generators were on the bus. Two were taken off, only No. 3 was left. Next day generator No. 1 was started, but it did not…Anonymous · 4 y▲0 rating0 commentsEmergency generator: insulation drops to 0.1 MΩ at every startTroubleshootingElectrical · Low insulation 440 VEvery time the emergency generator started, the 440 V insulation monitor fell to 0.1–0.2 MΩ. After 2–3 hours of running, the reading slowly came back to normal (5 MΩ and higher). The ship had been…Anonymous · 7 y▲0 rating0 commentsEmergency generator breaker closes and opens again at once, no tripTroubleshootingElectrical · Schneider Masterpact NT06 H2, Micrologic 5.0 AThe emergency generator breaker would not stay closed on the emergency switchboard bus, in both auto and manual mode. On "close" the breaker clicked and closed. The green "closed" indication was on…Anonymous · 4 y