0 rating0 commentsWeishaupt Monarch burner: random "Air combustion low" at startTroubleshootingBoiler · Weishaupt Monarch · Air combustion lowThe burner tripped only at boiler start, two or three times a day. The alarm changed: sometimes "Air combustion low", sometimes "Flame failure". It was random: no alarm for 10 hours, then up to five…Anonymous · 4 y0 rating0 commentsBoiler burner smokes, and more air makes it worseTroubleshootingBoilerThe boiler was smoking. Adding more combustion air made the smoke worse. The burner is set to run on the first stage only. The second stage was switched off on the panel.Anonymous · 3 y0 rating0 commentsIncinerator will not light: thick white smoke, flame sensor drops outTroubleshootingIncinerator & SewageThe incinerator would not light. The flame sensor lost the flame. Before, it had worked every day. The furnace had not been cleaned for a long time. Both chambers were full of ash, and all the air…Anonymous · 3 y0 rating0 commentsMain engine: gas bubbles in the fuel system, fuel pressure jumpingTroubleshootingMain EngineAir (gas) bubbles in the main engine fuel oil system. Small bubbles stayed all the time. Fuel pressure was jumping.Anonymous · 1 y0 rating0 commentsTwo-stroke load diagram: why the same mep is overload at low rpmKnowledgeMain Engine · MAN B&WOn a MAN B&W two-stroke load diagram, the same mep that is fine at high RPM counts as overload at low RPM because the torque limit is set mainly by the thermal load of engine components, with weak…Anonymous · 3 y0 rating0 commentsMain engine piston crowns burnt: long low-load running and bad injectorsTroubleshootingMain EngineBurn marks on our main engine piston crowns came, as far as we can tell, from long running at low load together with faulty fuel injectors. I found burn marks on the combustion side of the piston…Anonymous · 4 y0 rating0 commentsShipboard incinerator: how to keep it in good conditionKnowledgeIncinerator & SewageKeeping a shipboard incinerator in good condition mostly means clean air inlets and burner parts, a slow shutdown, careful sludge handling and sensible loading. These are the practices I follow,…Anonymous · 4 y0 rating0 commentsHow to take one cylinder out of service on MAN ME-CProcedureMain Engine · MAN ES ME-CTo take one cylinder unit out of operation on an ME-C (electronically controlled 2-stroke) main engine, I set the Chief Index limit for that cylinder to 0 on the MOP. This is an outline only. The…Anonymous · 4 y0 rating0 commentsVolvo Penta D16: con-rods through crankcase from swapped big-end caps (Wight Sky)IncidentMain Engine · Volvo Penta D16 MH · ME2 low LO pressure shutdown; ME4 common alarmRo-ro ferry with four Volvo Penta D16 MH high-speed MEs; one or two drive each Voith Schneider unit through fluid couplings. Wight Sky had three catastrophic ME failures in 15 months. The 2017 one…Anonymous · 4 y