▲0 rating0 commentsThermal oil fire from a failing pump bearing, water mist did not work (Pride of Hull)IncidentPumps · Allweiler NTT 80-200 · ER fire alarm, zone "Oil treatment pumps"Ro-ro passenger ferry, outbound in the Humber. Thermal oil (Texatherm 32, winter set point 170 °C) carried heat from the economisers and a boiler. Circulation pump #1 was on duty. The fire panel…Anonymous · 4 y▲1 rating0 commentsConsilium CS4000: "IOM70 Synchronisation signal" faultTroubleshootingFire & Safety · Consilium CS4000 · CENTRAL 1 IOM70 51 SYNCHRONISATION SIGNALFault alarm on the water mist main panel: "(212) CENTRAL 1 IOM70 51 SYNCHRONISATION SIGNAL", with "PUMP CONTROL BOX - UNIT FAULT INPUTS". On the I/O M70 module: PS LED flashing yellow, COM LED green.…Anonymous · 6 mo▲0 rating0 commentsSchaller Visatron VN215 oil mist detector: error E 012 a week after serviceTroubleshootingMain Engine · Schaller Visatron VN215/93 · E 012The oil mist detector was fully serviced: optics cleaned, filters changed, negative pressure set as per the manual. One week later it showed error E 012.Anonymous · 2 y▲0 rating0 commentsVolvo Penta D16: con-rods through crankcase from swapped big-end caps (Wight Sky)IncidentMain Engine · Volvo Penta D16 MH · ME2 low LO pressure shutdown; ME4 common alarmRo-ro ferry with four Volvo Penta D16 MH high-speed MEs; one or two drive each Voith Schneider unit through fluid couplings. Wight Sky had three catastrophic ME failures in 15 months. The 2017 one…Anonymous · 4 y▲0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y▲0 rating0 commentsWhy anchors and anchor chains are lost or damagedKnowledgeDeck MachineryAnchors and chains are lost or damaged through a mix of technical wear, operational mistakes and use beyond the design limits of the equipment. This is a general note, not one fault case. When…Anonymous · 4 y▲0 rating0 commentsHow to inspect the scavenge space on a two-stroke main engineProcedureMain Engine · MAN ESThis is how I do a scavenge space inspection on a 2-stroke main engine through the scavenge ports in the liner, plus the checks I make for water carry-over. Inspect often. Regular checks let you see…Anonymous · 4 y▲0 rating0 commentsGenerator engine fails on non-OEM bearings run to OEM intervals (Kommandor Susan)IncidentAuxiliary Engine · Caterpillar 3516B-TA · ER fire alarm, blackoutDiesel-electric vessel on sea trials, just out of the lock at Leith with a pilot on board. DG1 and DG4 were on line. The C/E heard a change in engine note on one generator, then a loud bang. The fire…Anonymous · 6 mo▲0 rating0 commentsMAN B&W two-stroke: limits for judging engine performanceKnowledgeMain Engine · MAN B&W MC/MC-C, ME/ME-C/ME-BThis is my checklist of practical limits for judging the performance of MAN B&W two-stroke main engines, both mechanical (MC/MC-C) and electronic (ME/ME-C/ME-B). I don't have the source of the limits…Anonymous · 3 y