▲0 rating0 commentsAlfa Laval boiler: both HMI panels show "Comm err station 0"TroubleshootingBoiler · Alfa Laval, Beijer HMI · Controller1_TCP: Comm err station 0After the boiler control power was switched off and on, neither HMI panel started working: not the local panel, not the one in the ECR. Both panels showed only the start screen with "Controller1TCP:…Anonymous · 1 y▲0 rating0 commentsBoiler feed pumps air-lock every few hours and trip on low pressureTroubleshootingBoilerBoiler feed water pumps get air-locked. After venting they run for 2–3 hours (sometimes up to 2 days), then the same again. Both pump motors trip. Low pressure alarms on the boiler panel, mostly at…Anonymous · 1 y▲0 rating0 commentsAalborg thermal oil boiler: no fuel from the nozzle at ignitionTroubleshootingBoiler · Aalborg, LAL burner controlAfter a safety alarm test the boiler stopped and did not start again. The coil of the recirculation (return) solenoid valve had burnt. It had run hot for a long time: it looked melted and its wiring…Anonymous · 1 y▲0 rating0 commentsKangrim boiler: "Flame failure" alarm while stopped, will not resetTroubleshootingBoiler · Kangrim · Flame failureFLAME FAILURE alarm came up while the boiler was stopped (not firing). The alarm could not be reset. A restart did not help.Anonymous · 2 y▲0 rating0 commentsBoiler burner smokes, and more air makes it worseTroubleshootingBoilerThe boiler was smoking. Adding more combustion air made the smoke worse. The burner is set to run on the first stage only. The second stage was switched off on the panel.Anonymous · 3 y▲0 rating0 commentsWeishaupt Monarch burner: random "Air combustion low" at startTroubleshootingBoiler · Weishaupt Monarch · Air combustion lowThe burner tripped only at boiler start, two or three times a day. The alarm changed: sometimes "Air combustion low", sometimes "Flame failure". It was random: no alarm for 10 hours, then up to five…Anonymous · 4 y▲0 rating0 commentsBoiler water level DP transmitter shows a wrong level after drydockTroubleshootingBoilerAfter drydock the boiler water level DP transmitter stopped showing the right level. The reading made no sense. Before drydock it worked. Nobody said they had touched it.Anonymous · 4 y▲0 rating0 commentsKangrim boiler: "Flame failure" at the end of the ignition timeTroubleshootingBoiler · Kangrim · Flame failureComposite boiler. It had run in manual for more than a week. When it was switched to auto, the "Flame failure" alarm came. The burner starts and the flame burns. The alarm comes at the moment the…Anonymous · 5 y▲0 rating0 commentsAalborg boilers: local panels go offline, fan trips at ignitionTroubleshootingBoiler · AalborgTwo boilers, one ECR PC. First the boiler 1 local panel went offline now and then; a reset helped for a day. Then the boiler 2 local panel went offline, flashing online / offline, and did not reset.…Anonymous · 6 y▲0 rating0 commentsAalborg boiler will not light after changeover from HFO to MDOTroubleshootingBoiler · Aalborg composite boiler · Flame outAfter changeover from heavy fuel to MDO, the burner did not light. At each start it tripped on flame out.Anonymous · 6 y▲0 rating0 commentsWeishaupt Monarch burner sprays fuel as soon as the fan startsTroubleshootingBoiler · Weishaupt MonarchFuel sprayed from the nozzle as soon as the burner fan motor started, during pre-purge. It should spray only after purge, when the air damper closes, together with ignition. The burner started and…Anonymous · 6 y