▲0 rating0 commentsME exhaust valve spindle burn-through: common causesKnowledgeMain EngineExhaust valve spindle burn-through on a two-stroke main engine usually comes from one of a short list of factors, each of which makes the spindle burn away faster and shortens the time between…Anonymous · 4 y▲0 rating0 commentsAalborg thermal oil boiler: no fuel from the nozzle at ignitionTroubleshootingBoiler · Aalborg, LAL burner controlAfter a safety alarm test the boiler stopped and did not start again. The coil of the recirculation (return) solenoid valve had burnt. It had run hot for a long time: it looked melted and its wiring…Anonymous · 1 y▲0 rating0 commentsHyundai generator: no voltage at start after a 440 V insulation alarmTroubleshootingElectrical · Hyundai HFC7The 440 V insulation reading started to jump between 0 and infinity. Three generators were on the bus. Two were taken off, only No. 3 was left. Next day generator No. 1 was started, but it did not…Anonymous · 4 y▲0 rating0 commentsGenerator will not come off the bus at stop: "Stop failure", reverse powerTroubleshootingElectrical · Stop failureThe undervoltage (UV) coil of a generator air circuit breaker (ACB) was burnt. To keep the breaker usable, the UV coil plunger was held in with its mechanical lock. The generator synchronised and…Anonymous · 1 y▲0 rating0 commentsOil tanker aux boilers: tests before cargo dischargeProcedureBoilerBefore cargo discharge on an oil tanker, I test the auxiliary boilers so they keep working through the discharge: boiler water, controls, and the pumps under load. This applies to any boiler maker…Anonymous · 4 y▲0 rating0 commentsGenerator engine fails on non-OEM bearings run to OEM intervals (Kommandor Susan)IncidentAuxiliary Engine · Caterpillar 3516B-TA · ER fire alarm, blackoutDiesel-electric vessel on sea trials, just out of the lock at Leith with a pilot on board. DG1 and DG4 were on line. The C/E heard a change in engine note on one generator, then a loud bang. The fire…Anonymous · 6 mo▲0 rating0 commentsMAN 48/60: con-rod small end breaks after bad bush renewal (Finlandia Seaways)IncidentMain Engine · MAN 12V48/60 · Crankcase oil mist high, No. 6 main bearing temp highRo-ro at sea, single MAN 12V48/60 at 500 rpm, 110 662 running hours. The on-watch 3/E was in the purifier room when he heard loud metallic knocking. The bridge felt heavy vibration and saw pitch and…Anonymous · 5 y▲0 rating0 commentsAux engine room fire: slipped fuel pump coupling and exhaust leak (Finnmaster)IncidentAuxiliary Engine · Mitsubishi S12R · ER smoke alarm, then blackoutRo-ro leaving Hull with a pilot on board. AE1 had just been paralleled with AE2. Eight minutes after leaving the berth, smoke was detected in the aux engine room. Both AE2 exhaust temperature gauges…Anonymous · 1 y▲0 rating0 commentsGenerator con-rod seizes and holes the block: oil run far past interval (Ocean Navigator)IncidentAuxiliary Engine · Caterpillar 3516B · ER fire alarm, AE2 low LO pressure and oil filter plugged, blackoutAE2 on a coastal cruise ship (Caterpillar 3516B, 1,800 rpm) had run its LO for more than 5,000 h and its filter elements for 3,329 h. Both should be changed at 1,000 h (LO longer only under…Anonymous · 1 y