▲0 rating0 commentsConsilium fire detection: five "Sensor fail" alarms from one zoneTroubleshootingFire & Safety · Consilium · Sensor fail, Communication errorFive "Sensor fail" alarms with "Communication error" came up suddenly, all from one zone (pump room). The failed points were on two loops: 3 smoke detectors on loop 2 and 2 manual call points on loop…Anonymous · 6 y▲0 rating0 commentsIncinerator will not light: thick white smoke, flame sensor drops outTroubleshootingIncinerator & SewageThe incinerator would not light. The flame sensor lost the flame. Before, it had worked every day. The furnace had not been cleaned for a long time. Both chambers were full of ash, and all the air…Anonymous · 3 y▲0 rating0 commentsMAN ME-C: "Low stroke" slowdown, exhaust valve position signal drops outTroubleshootingMain Engine · MAN B&W ME-C · Low strokeMain engine slowdown with "Low stroke" alarm on one cylinder. On the MOP, the exhaust valve position signal from the inductive sensor dropped out about every 3 seconds. Each time, fuel injection to…Anonymous · 8 mo▲0 rating0 commentsNewins IC5000 cold room indicator shows LLLL after resetTroubleshootingRefrigeration & HVAC · Newins IC5000The cold chamber remote temperature indicator read 6 °C different from the real temperature. The settings were reset as the manual says: hold two keys while switching the power on. After the reset,…Anonymous · 1 y▲0 rating0 commentsHi Air Korea AC: compressor will not start, "FRESH ARM 1CRUN"TroubleshootingRefrigeration & HVAC · Hi Air Korea · FRESH ARM 1CRUNThe AC compressor did not start. No alarms were showing. When starting the compressor, only the controller on the AC control panel showed a new alarm: FRESH ARM 1CRUN. The manuals do not explain this…Anonymous · 4 mo▲0 rating0 commentsAlfa Laval separator: alarm A85 (MT60 fault), water content shows only dashesTroubleshootingPurifier · Alfa Laval · A85 (MT60 fault)Separator with a water content transducer. The transducer had problems for about two weeks. The transducer board was replaced with a new one. After that, alarm A85 (MT60 fault) came up. The old board…Anonymous · 2 y▲0 rating0 commentsCarrier reefer container: Alarm 15 "Loss of cooling", no ice on evaporatorTroubleshootingRefrigeration & HVAC · Carrier Streamline · Alarm 15 Loss of coolingReefer container found with Alarm 15 "Loss of cooling". It felt like something was blocking the air flow. When warm water was poured over the evaporator, nothing came out of the drain tube.Anonymous · 8 y▲0 rating0 commentsKangrim boiler: "Flame failure" at the end of the ignition timeTroubleshootingBoiler · Kangrim · Flame failureComposite boiler. It had run in manual for more than a week. When it was switched to auto, the "Flame failure" alarm came. The burner starts and the flame burns. The alarm comes at the moment the…Anonymous · 5 y▲0 rating0 commentsAC compressor loses oil pressure at start after overhaul with new partsTroubleshootingRefrigeration & HVAC · Low oil pressureThe air-conditioning compressors were overhauled with a new spare parts kit. After the overhaul, oil pressure dropped at every start.Anonymous · 1 y▲0 rating0 commentsRolls-Royce steering gear: "Hydraulic lock" alarm at every small rudder movementTroubleshootingSteering Gear · Rolls-Royce · Hydraulic lock"Hydraulic lock" alarm on the steering gear. It started after a service in dry dock. At first it came now and then. Sometimes it cleared by itself, sometimes tightening the contacts helped. Later it…Anonymous · 2 y▲0 rating0 commentsMooring winch with frequency converter: speed does not change with the joystickTroubleshootingDeck MachineryAn inverter-driven mooring winch stopped regulating speed from the joystick.Anonymous · 1 y▲0 rating0 commentsAlfa Laval S956: "Bowl speed low" alarm during separationTroubleshootingPurifier · Alfa Laval S956 · Bowl speed low"Bowl speed low" alarm about twice a day. The alarm came during separation, not during discharge. Often it came about 10 hours into the cycle. Between alarms the separator started, reached speed and…Anonymous · 5 y▲0 rating0 commentsNabtesco governor: main engine will not go above 66 rpm, SCAVEN. LIMIT lamp onTroubleshootingMain Engine · Nabtesco governor control unit · M/E GOVERNOR SYSTEM ABNRThe main engine would not run faster than 66 rpm (Half Ahead). Scavenge air pressure was 0.2 bar. The auxiliary blowers were still running. On the governor control unit the SCAVEN. LIMIT lamp was on.…Anonymous · 3 y